Incidence of intravascular penetration in transforaminal cervical epidural steroid injections

STUDY DESIGN A prospective, observational, human, study was conducted. OBJECTIVES To evaluate the incidence of vascular penetration during fluoroscopically guided, contrast-enhanced transforaminal cervical epidural steroid injections, and to determine whether the observation of blood in the needle h...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Spine (Philadelphia, Pa. 1976) Pa. 1976), 2003, Vol.28 (1), p.21-25
Hauptverfasser: FURMAN, Michael B, GIOVANNIELLO, Michael T, O'BRIEN, Erin M
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:STUDY DESIGN A prospective, observational, human, study was conducted. OBJECTIVES To evaluate the incidence of vascular penetration during fluoroscopically guided, contrast-enhanced transforaminal cervical epidural steroid injections, and to determine whether the observation of blood in the needle hub can be used to predict a vascular injection. SUMMARY OF BACKGROUND DATA Incorrectly placed intravascular cervical spinal injections result in medication flow systemically and not to the desired target. A recently published study demonstrates a high incidence of intravascular injections in transforaminal lumbosacral epidural injections. No studies so far have evaluated the incidence of vascular injections in transforaminal cervical epidural steroid injections, nor have they calculated the ability of observed blood in the needle hub to predict a vascular injection in the cervical spine.METHODS The incidence of fluoroscopically confirmed intravascular uptake of contrast was prospectively observed in 337 patients treated with cervical transforaminal epidural steroid injections. The ability of observed blood in the needle hub to predict intravascular injection was also investigated. For each subject, the injection level was chosen on the basis of the clinical scenario including history, physical examination, and review of imaging studies. Some patients had multilevel injections. Using fluoroscopic guidance, the authors placed a 25-gauge needle into the epidural space using a transforaminal approach according to accepted standard technique. Needle tip location was confirmed with biplanar imaging. The presence or absence of blood in the needle hub spontaneously ("flash") and after attempted aspiration by pulling back on the syringe's plunger was documented. Contrast then was injected under real-time fluoroscopy to determine whether the location of the needle tip was intravascular. The results were recorded in a prospective manner indicating the presence or absence of blood in the needle hub and whether a vascular pattern was noted with contrast injection, and these were correlated. Relevant epidemiologic data also were recorded. RESULTS The study included 504 transforaminal epidural steroid injections. The overall rate of fluoroscopically confirmed intravascular contrast injections was 19.4%. Use of observed blood in the needle hub to predict intravascular injections was 97% specific, but only 45.9% sensitive. There was no significant difference in intravascular rat
ISSN:0362-2436
1528-1159
DOI:10.1097/00007632-200301010-00007