Case Report: Techniques for the Removal of Broken Small-Diameter Tibial Nails: A Report of Two Cases

The availability of small-diameter interlocking nails for unreamed applications has expanded the indications for intramedullary nailing of open tibial shaft fractures. Smaller diameter nails that are inserted without reaming are mechanically weaker than the larger-diameter nails that are inserted af...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of orthopaedic trauma 1995-12, Vol.9 (6), p.523-525
Hauptverfasser: Kelley, Scott S, Morrison, John A, Templeman, David C
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The availability of small-diameter interlocking nails for unreamed applications has expanded the indications for intramedullary nailing of open tibial shaft fractures. Smaller diameter nails that are inserted without reaming are mechanically weaker than the larger-diameter nails that are inserted after intramedullary reaming. Potentially, nails with a smaller diameter will fail at a higher rate, creating unique difficulties associated with their removal. This article presents two cases that illustrate solutions to those problems.