Histologic Evaluation During Healing of Hydrogel Core-and-Skirt Keratoprostheses in the Rabbit Eye

PURPOSEWe developed two models that are modifications of our original poly(2-hydroxyethyl methacrylate) (PHEMA) core-and-skirt keratoprosthesis. In these keratoprostheses. the mechanical strength of the skirt has been considerably increased with divinyl glycol (DVG) as a cross-linking agent during p...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Cornea 1997-05, Vol.16 (3), p.352-359
Hauptverfasser: Vijayasekaran, Sarojini, Hicks, Celia R, Chirila, Traian V, Fitton, J Helen, Clayton, Anthony B, Lou, Xia, Platten, Sharon, Crawford, Geoffrey J, Constable, Ian J
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:PURPOSEWe developed two models that are modifications of our original poly(2-hydroxyethyl methacrylate) (PHEMA) core-and-skirt keratoprosthesis. In these keratoprostheses. the mechanical strength of the skirt has been considerably increased with divinyl glycol (DVG) as a cross-linking agent during polymerization. In one (KPro I). methyl methacrylate (MM A) was added as comonomer to increase cell adhesion, and in the other (KPro II). HEMA was polymerized with DVG without comonomer. The aim of this study was to evaluate the process of healing and biocolonization and to ascertain whether KPro I demonstrates better ingrowth than the mechanically stronger KPro II, after implantation in rabbit eyes. METHODSTen rabbits were used for each model and studied at five predetermined end points up to 26 weeks. The device was implanted as a full-thickness keratoprosthesis covered with a conjunctival flap. RESULTSNeither prosthesis demonstrated extrusion or retroprosthetic membrane formation. There was no significant difference between the two types of prosthesis with respect to tissue ingrowth and surrounding tissue melting. Histologically. inflammation was not severe, but calcification was seen in most specimens. Evidence of biodegradation of the prosthesis also was seen. CONCLUSIONIn our original keratoprosthesis, fibrovascular invasion had occurred into the prosthetic skirt, but wound dehiscence and low mechanical strength resulted in an unfavorable outcome. In this series, the mechanical properties were improved, and KPro II was stronger than KPro I. Therefore KPro II would be the preferred polymer combination for surgical manipulation. However, biodegradation and calcification require further investigation into the degree and significance of these adverse reactions.
ISSN:0277-3740
1536-4798
DOI:10.1097/00003226-199705000-00017