P14.41 Cost-effectiveness of FET PET for early treatment response assessment in glioma patients following adjuvant temozolomide chemotherapy

Abstract BACKGROUND In light of increasing healthcare costs, higher medical expenses should be justified socio-economically. Therefore, we calculated the effectiveness and cost-effectiveness of PET using the radiolabeled amino acid O-(2-[18F]-fluoroethyl)-L-tyrosine (FET) compared to conventional MR...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Neuro-oncology (Charlottesville, Va.) Va.), 2021-09, Vol.23 (Supplement_2), p.ii46-ii46
Hauptverfasser: Rosen, J, Ceccon, G, Bauer, E K, Werner, J M, Kabbasch, C, Fink, G R, Langen, K J, Galldiks, N
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Abstract BACKGROUND In light of increasing healthcare costs, higher medical expenses should be justified socio-economically. Therefore, we calculated the effectiveness and cost-effectiveness of PET using the radiolabeled amino acid O-(2-[18F]-fluoroethyl)-L-tyrosine (FET) compared to conventional MRI for early identification of responders to adjuvant temozolomide chemotherapy. A recent study in IDH-wildtype glioma patients suggested that after two cycles, FET-PET parameter changes predicted a significantly longer survival while MRI changes were not significant. MATERIALS AND METHODS To determine the effectiveness and cost-effectiveness of serial FET-PET imaging, we analyzed published clinical data and calculated the associated costs in the context of the German healthcare system.Based on a decision-tree model, FET-PET and MRI’s effectiveness was calculated, i.e., the probability to correctly identify a responder as defined by an overall survival ≥15 months. To determine the cost-effectiveness, the incremental cost-effectiveness ratio (ICER) was calculated, i.e., the cost for each additionally identified responder by FET-PET who would have remained undetected by MRI. The robustness of the results was tested by deterministic and probabilistic (Monte Carlo simulation) sensitivity analyses. RESULTS Compared to MRI, FET-PET increases the rate of correctly identified responders to chemotherapy by 26%; thus, four patients need to be examined by FET-PET to identify one additional responder. Considering the respective cost for serial FET-PET and MRI, the ICER resulted in €4,396.83 for each additional correctly identified responder by FET-PET. The sensitivity analyses confirmed the robustness of the results. CONCLUSION In contrast to conventional MRI, the model suggests that FET PET is cost-effective in terms of ICER values. Concerning the high cost of temozolomide, the integration of FET-PET has the potential to avoid premature chemotherapy discontinuation at a reasonable cost.
ISSN:1522-8517
1523-5866
DOI:10.1093/neuonc/noab180.158