MO643: Haemoperfusion Combined with Standard Haemodialysis May Have a Beneficial Effect on Serum Beta-2 Microglobulin Levels in Chronic Haemodialysis Patients

Abstract BACKGROUND AND AIMS Standard haemodialysis (HD) with low-flux membranes does not provide adequate middle molecular weight (MMW) clearance of uraemic toxins [1] and on-line haemodiafiltration (OL-HDF) may not be easily applicable and cost effective in some centres. We investigated whether lo...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Nephrology, dialysis, transplantation dialysis, transplantation, 2022-05, Vol.37 (Supplement_3)
Hauptverfasser: Sonikian, Makrouhi, Chiras, Theodoros, Velentza, Aikaterinh, Skarakis, Jacob, Biblaki, Dimitra, Dagkounaki, Paraskevi, Barbatsi, Aggeliki, Martsoukou, Maria
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Abstract BACKGROUND AND AIMS Standard haemodialysis (HD) with low-flux membranes does not provide adequate middle molecular weight (MMW) clearance of uraemic toxins [1] and on-line haemodiafiltration (OL-HDF) may not be easily applicable and cost effective in some centres. We investigated whether low-flux conventional HD combined with hemoperfusion (HP) may offer any benefit regarding serum beta-2 microglobulin (β2M) levels as a surrogate of middle molecules in patients haemodialyzed for many years and we compared the method-combination with OL-HDF. METHOD We studied 24 stable anuric patients during 6 months, under standard medical therapy, aged 69 years (46–90), M: F = 20:4, on chronic HD for 84 (65–286) months, who formed three groups: A (GrA), B (GrB) and C (GrC). Each group included 8 age- and HD vintage-matched patients respectively. In GrA patients, a type HA130 cartridge for HP was connected in parallel to the low-flux polysulfone dialyzer and this combination of standard HD with HP (HD + HP) was used once a week for the first month, once every 2 weeks for the second month and once a month for the next 4 months. GrB patients underwent only standard HD treatment with low-flux polysulfone membranes and GrC patients were treated with OL-HDF. In all three groups serum β2M levels were determined at months 0 (M0) and 6 (M6), before (pre-dialysis, preD) and after (post-dialysis, postD) the second weekly session. RESULTS Serum preD β2M levels ​​were similar in GrA and GrB at M0 (44.1 ± 8.6 versus 34.6 ± 16.2 mg/L;  P = NS) and at M6 (46.1 ± 7.6 versus 41.1 ± 18.9 mg/L;  P = NS). In GrC, preD-β2M values were lower compared with GrA at both M0 (31.1 ± 4.2 mg/L;  P = .008) and M6 (33.8 ± 6.82 mg/L;  P = .02). In GrC, serum postD-β2M levels ​​decreased significantly at both M0 (7.4 ± 1.9 mg/L;  P 