Liquid chromatographic determination of glyphosate in water-soluble granular formulations: collaborative study

A liquid chromatographic (LC) method for the determination of glyphosate in various water-soluble granular formulations was tested by 28 laboratories. Samples were dissolved in mobile phase and injected directly into an LC system with a 25 cm SAX column and a mobile phase of 96% aqueous buffer solut...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of AOAC International 1997-05, Vol.80 (3), p.464-468
Hauptverfasser: Morlier, L.W. (Monsanto Company, Luling, LA.), Tomkins, D.F
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A liquid chromatographic (LC) method for the determination of glyphosate in various water-soluble granular formulations was tested by 28 laboratories. Samples were dissolved in mobile phase and injected directly into an LC system with a 25 cm SAX column and a mobile phase of 96% aqueous buffer solution, 0.0062M KH2PO4, and 4% methanol. Detection was by UV absorption at 195 nm. Manual or automated injections were made via fixed-volume loops. Calculations were based on peak area comparisons with external standards. The collaborative study analyzed 5 matched pairs of 4 water-soluble granular formulations, with one determination per sample. The study generated 138 matched pairs, which were analyzed by using the AOAC spreadsheet and Youden's matched-pair calculations. Coefficients of variation for the 4 formulations ranged from 0.65 to 1.37%. The LC method for the determination of glyphosate in water-soluble granular formulations has been adopted first action by AOAC INTERNATIONAL
ISSN:1060-3271
1944-7922
DOI:10.1093/jaoac/80.3.464