A first-in-human study of PDC31 (prostaglandin F2α receptor inhibitor) in primary dysmenorrhea

STUDY QUESTION What is the safe and pharmacodynamically active dose range for PDC31 (prostaglandin F2α receptor inhibitor) in patients with primary dysmenorrhea (PD)? SUMMARY ANSWER The 1 mg/kg/h dose of PDC31 appears to be safe and potentially effective in reducing intrauterine pressure (IUP) and p...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Human reproduction (Oxford) 2014-11, Vol.29 (11), p.2465-2473
Hauptverfasser: Böttcher, B., Laterza, R.M., Wildt, L., Seufert, R.J., Buhling, K.J., Singer, C.F., Hill, W., Griffin, P., Jilma, B., Schulz, M., Smith, R.P.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:STUDY QUESTION What is the safe and pharmacodynamically active dose range for PDC31 (prostaglandin F2α receptor inhibitor) in patients with primary dysmenorrhea (PD)? SUMMARY ANSWER The 1 mg/kg/h dose of PDC31 appears to be safe and potentially effective in reducing intrauterine pressure (IUP) and pain associated with excessive uterine contractility when given as a 3-h infusion in patients with PD. WHAT IS KNOWN ALREADY PDC31 has previously been shown to reduce the duration and strength of PGF2α-induced contractions in human uterine myometrial strip models and to delay delivery in animal models of preterm labor. STUDY DESIGN, SIZE, DURATION This was a prospective, multi-center, dose-escalating first-in-human Phase I study conducted from March 2011 to June 2012. A total of 24 women with PD were enrolled and treated with one of five doses (0.01, 0.05, 0.15, 0.3, 0.5 and 1 mg/kg/h) of PDC31 given as a 3-h infusion. Patients were observed for a further 24 h. PARTICIPANTS/MATERIALS, SETTING, METHODS This study was conducted at four hospitals in Europe in non-pregnant, menstruating women with PD. Women with PD (n = 24) received PDC31 infused over 3 h within 8–10 h of the onset of menstruation. IUP and pain monitoring through the visual analog scale (VAS) was assessed prior to, during and following the infusion. Patients were observed for dose-limiting toxicities and other adverse events. Pharmacokinetic samples were also taken to profile the drug. MAIN RESULTS AND THE ROLE OF CHANCE A 3-h infusion of PDC31 was safe up to and including doses of 1 mg/kg/h. Most adverse events were mild (n = 15; 83.3%) and not considered associated with PDC31 (n = 14; 77.8%). PDC31 infusion decreased uterine activity based on IUP and pain (VAS) scores. IUP was decreased by 23% over all dose levels, reaching a minimum at 135–150 min. There appeared to be a dose-dependent effect on IUP, with the high dose group (1 mg/kg/h) showing the largest decrease in IUP. There was a statistically significant linear dose–effect and concentration–effect relationship for several IUP parameters over the evaluation period of 60–180 min. A dose differentiating effect on pain was seen with the two highest doses. PDC31 demonstrated uncomplicated, linear pharmacokinetics with a terminal half-life of ∼2 h. LIMITATIONS, REASONS FOR CAUTION This was a first-in-human study and exposure to PDC31 was limited for safety reasons. As such, pharmacodynamic parameters were assessed at a two-sided Type I error of 20
ISSN:0268-1161
1460-2350
DOI:10.1093/humrep/deu205