P2807Clinical outcomes with cobalt chromium biolimus eluting drug-eluting stents compared with stainless steel biolimus eluting drug-eluting stents in all-comers patients
Abstract Aims Thinner stent struts may improve deliverability, conformability and reduce vessel injury. We report the first clinical outcomes of the thinner strut (84–88um) cobalt chromium biolimus eluting stent from the Biomatrix Alpha registry and compare these with objective performance criteria...
Gespeichert in:
Veröffentlicht in: | European heart journal 2019-10, Vol.40 (Supplement_1) |
---|---|
Hauptverfasser: | , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Abstract
Aims
Thinner stent struts may improve deliverability, conformability and reduce vessel injury. We report the first clinical outcomes of the thinner strut (84–88um) cobalt chromium biolimus eluting stent from the Biomatrix Alpha registry and compare these with objective performance criteria from the stainless steel BioMatrix Flex arm of the Leaders study.
Methods
A total of 1257 patients were studied: 400 patients from 12 centres receiving ≥1 Biomatrix Alpha stent were prospectively enrolled into the Biomatrix Alpha registry and then underwent a pre-specified comparison with 857 patients who received a Biomatrix Flex stent in the Leaders study. The primary endpoint was major adverse cardiac events (MACE) defined as the composite of cardiac death, myocardial infarction (MI) or clinically driven target vessel revascularization (TVR) at 9 months. Assuming a 9.2% event rate with BioMatrix Flex, a one-sided type I error (α) of 0.05, and a 4% non-inferiority margin, a sample size of 400 in the Biomatrix alpha registry had >80% power to conclude non-inferiority.
Results
Baseline characteristics in the Alpha registry were typical of an all-comers population with a mean age of 64.7±11.3, diabetes 19%, current smoking 21%, dyslipidemia 57%, hypertension 57%, total stent length per lesion 25.49±13.45, mean stents per procedure 1.59±0.88 and overlapping stents in 13.4%. Observed MACE at 9 months with Alpha was 3.94% (upper limit 5.98%) vs. 9.28% MACE rate with Flex stents in Leaders, which met pre-specified criteria for non-inferiority (p |
---|---|
ISSN: | 0195-668X 1522-9645 |