P1736A novel calcium parameter, calcium ratio, can predict minimum lumen area in calcified lesions: optical coherence tomographic study
Abstract Background Several reports have revealed that minimum lumen area (MLA) is associated with target lesion failure even with newer-generation drug-eluting stents, and calcified lesions usually induced inadequate lumen area because of stent under expansion. Contemporary debulking devices such a...
Gespeichert in:
Veröffentlicht in: | European heart journal 2019-10, Vol.40 (Supplement_1) |
---|---|
Hauptverfasser: | , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Abstract
Background
Several reports have revealed that minimum lumen area (MLA) is associated with target lesion failure even with newer-generation drug-eluting stents, and calcified lesions usually induced inadequate lumen area because of stent under expansion. Contemporary debulking devices such as rotational/orbital atherectomy can modify severe calcified lesions before stenting. However, there are no optimal criteria to indicate necessity for calcium modification to obtain adequate acute gain. Therefore, we investigated useful calcium parameters correlating with MLA in the calcified lesions after stenting.
Methods
We enrolled 71 consecutive calcified lesions (71 patients) who underwent optical coherence tomography (OCT) guided percutaneous coronary intervention (PCI) between September 2016 and January 2019. Exclusion criteria included acute coronary syndrome, in-stent restenosis and lesions without any calcium or treated with rotational atherectomy. If there were several calcium lesions in one patient, we selected maximum calcium angle lesion. We compared mean reference area, pre lumen area and various calcium parameters including calcium arc, maximum thickness, depth, area, longitudinal length and calcium ratio that was maximum calcium thickness divided by nearest reference diameter in disease-free segments as much as possible in pre-PCI OCT evaluation with post-PCI lumen area at that site by simple and multiple regression analysis.
Results
Calcium ratio was an independent predictor for post-PCI lumen area in addition to mean reference area, while the others were not associated with post-PCI lumen area (table).
Results of OCT parameters
Univariate analysis
Multivariate analysis
P value
P value
β
Mean reference area |
---|---|
ISSN: | 0195-668X 1522-9645 |
DOI: | 10.1093/eurheartj/ehz748.0490 |