6118Mid- and long-term percentage of ventricular pacing in patients implanted with a pacemaker after a transcatheter aortic valve replacement procedure: potential clinical implications

Abstract Background Cardiac conduction disturbances frequently occur following transcatheter aortic valve replacement (TAVR). As this procedure is getting more and more common, more research efforts should focus on post procedural rhythm disturbances and their evolution over time Purpose To evaluate...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:European heart journal 2019-10, Vol.40 (Supplement_1)
Hauptverfasser: Baldi, E, Demarchi, A, Mauri, S, Di Giacomo, C, Ferrario Ormezzano, M, Ferlini, M, Savastano, S, Petracci, B, Sanzo, A, Aiello, M, Gazzoli, F, Pelenghi, S, Oltrona Visconti, L, De Ferrari, G M, Rordorf, R
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Abstract Background Cardiac conduction disturbances frequently occur following transcatheter aortic valve replacement (TAVR). As this procedure is getting more and more common, more research efforts should focus on post procedural rhythm disturbances and their evolution over time Purpose To evaluate the percentage of pacing in patients who underwent a TAVR procedure and developed a conduction disturbance requiring a transvenous pacemaker (PM) implantation Methods We considered all the patients who underwent a TAVR procedure between march 2009 and november 2018 in our centre. Patients implanted with a PM or an ICD before the TAVR procedure or 30 days after the TAVR were not considered eligible for our analysis, because likely not related to TAVR. The percentage of effective right ventricular pacing was assessed both at mid- and long-term follow-up Results 265 patients underwent TAVR in the study period (45% males, 81±6 years). 20 patients already had a PM and were excluded. 39 of the 245 patients (16%) were implanted with a PM after TAVR, 26 of them were implanted within 30 days (median time TAVR-PM implant: 8±7 days). The rate of PM implant within 30 days after TAVR was 8% (20/246) for patients implanted with an Edward Sapien valve, 25% (4/16) for patients with an Evolute Pro valve and 66% (2/3) in patients with a Lotus Edge valve. The indication for PM implant was a permanent 3rd degree A-V block in 12 patients, a paroxysmal A-V block in 4, a bifascicular A-V block with an infra-hisian disease in 5, a II degree Mobitz II A-V block in 2, an atrial fibrillation with slow A-V conduction in 2 and a 2:1 A-V block with infra-hisian disease in 1. The first follow-up after the PM implantation was available in 24 patients (mean 78±87 days after PM implant) and the second in 15 patients (372±267 days after PM implant). The patients were divided into two groups based on the presence/absence of permanent 3rd degree AV block at the time of implantation. At the first follow-up the percentage of pacing was significantly higher in patients implanted with vs. without a permanent 3rd degree AV block (98.5% vs 11%, p
ISSN:0195-668X
1522-9645
DOI:10.1093/eurheartj/ehz746.0144