Improving omnipolar electrogram reconstruction: an animal model study

Abstract Background Cardiac arrhythmias are a significant cause of morbidity and mortality worldwide. The characterization of cardiac tissue's electrophysiological substrate is crucial for the diagnosis and treatment of these conditions. High-density (HD) electrode arrays, such as the Advisor™...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:European heart journal 2023-11, Vol.44 (Supplement_2)
Hauptverfasser: Ruiperez-Campillo, S, Castells, F, Casado-Arroyo, R, Merino, J L, Millet, J
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Abstract Background Cardiac arrhythmias are a significant cause of morbidity and mortality worldwide. The characterization of cardiac tissue's electrophysiological substrate is crucial for the diagnosis and treatment of these conditions. High-density (HD) electrode arrays, such as the Advisor™ HD Grid Mapping Catheter and Sensor Enabled™ (SE), are commonly used to examine cardiac tissue locally and create activation maps. However, the current method for reconstructing omnipolar EGMs, a novel technique claimed to be orientation-independent, has limitations. The enhancement of this reconstruction methodology has the potential to improve the accuracy and reliability of electrophysiological mapping. This, in turn, can have a positive impact on patients suffering from cardiac arrhythmias, ultimately leading to better clinical outcomes. Purpose We propose a novel reconstruction method to estimate omnipolar EGM that overcomes the angle dependence weakness of the current method to enhance the reconstruction of electrophysiological signals. Methodology Prior experiments were conducted on isolated rabbit hearts using a 128-electrode array with electrodes spaced 1mm apart over the ventricular epicardium. Four-electrode cliques were designed from these experiments, with different inter-electrode distances as depicted in Figure 1A, to reconstruct the current and novel omnipolar configurations. Metrics were designed to assess the quality of the electrogram signals, including the bipolar loop area and the ratio of the bipolar components of the omnipole (see fig. 2). The bipoles were calculated from unipolar electrograms, and the signal was corrected with a 45º offset in the cross. The propagation angle was then detected, and the local activation time (LAT) was estimated. Results In the bipole plots, it was observed that the morphology of the bipolar loop becomes distorted with an increase in the inter-electrode distance, becoming thinner for distances less than 2mm. There is a direct relation between the areas in the bipolar loop and the inter-electrode distance (see Figure 2A). Furthermore, the values of the area in the cross are always comparable to the best-performing triangular clique. For the ratio of bipoles, the relation is inversely related to distance (see Figure 2B). Similarly, the performance of the cross is comparable to the best-performing triangular omnipole. Conclusion This study highlights the importance of accurate reconstruction of omnipolar EGMs for th
ISSN:0195-668X
1522-9645
DOI:10.1093/eurheartj/ehad655.290