Comparison of wavelet continuous transform and signal averaged ECG for high frequency content and late potential detection in healthy individuals

Abstract Introduction The Signal Averaged ECG (SAECG) is a classical method forSudden Cardiac Death (SCD) risk assessment, by means of Late Potentials (LP) in the filtered QRS (fQRS)[1]. But it is highly dependent on noise and require long time records, which make it tedious to use. Wavelet Continuo...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:European heart journal 2020-11, Vol.41 (Supplement_2)
Hauptverfasser: Garcia Iglesias, D, Rubin Lopez, J.M, Perez Diez, D, Moris De La Tassa, C, De Cos Juez, F.J, Calvo Cuervo, D
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Abstract Introduction The Signal Averaged ECG (SAECG) is a classical method forSudden Cardiac Death (SCD) risk assessment, by means of Late Potentials (LP) in the filtered QRS (fQRS)[1]. But it is highly dependent on noise and require long time records, which make it tedious to use. Wavelet Continuous Transform (WCT) meanwhile is easier to use, and may let us to measure the High Frequency Content (HFC) of the QRS and QT intervals, which also correlates with the risk of SCD [2,3]. Whether the HFC of the QRS and QT measured with the WCT is a possible subrogate of LP, has never been demonstrated. Objective To demonstrate if there is any relationship between the HFC measured with the WCT and the LP analyzed with the SAECG. Methods Data from 50 consecutive healthy individuals. The standard ECG was digitally collected for 3 consecutive minutes. For the WCT Analysis 8 consecutive QT complexes were used and for the SAECG Analysis all available QRS were used. The time-frequency data of each QT complex were collected using the WCT as previously described [3] and the Total, QRS and QT power were obtained from each patient. For the SAECG, bipolar X, Y and Z leads were used with a bidirectional filter at 40 to 250 Hz [1]. LP were defined as less than 0.05 z in the terminal part of the filtered QRS and the duration (SAECG LP duration) and root mean square (SAECG LP Content) of this LP were calculated. Pearson's test was used to correlate the Power content with WCT analysis and the LP in the SAECG. Results There is a strong correlation between Total Power and the SAECG LP content (r=0.621, p
ISSN:0195-668X
1522-9645
DOI:10.1093/ehjci/ehaa946.3447