Self-navigated MRI 3D whole heart sequence for non-enhanced aortic root measurement in transcatheter aortic valve intervention: comparison to cardiac CT
Abstract Purpose To evaluate image quality, inter-observer reliability and diagnostic accuracy of self-navigated noncontrast 3D whole-heart magnetic resonance angiography (MRA) for transcatheter aortic valve intervention (TAVI) evaluation in comparison to standardized contrast-enhanced computed tomo...
Gespeichert in:
Veröffentlicht in: | European heart journal 2020-11, Vol.41 (Supplement_2) |
---|---|
Hauptverfasser: | , , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Abstract
Purpose
To evaluate image quality, inter-observer reliability and diagnostic accuracy of self-navigated noncontrast 3D whole-heart magnetic resonance angiography (MRA) for transcatheter aortic valve intervention (TAVI) evaluation in comparison to standardized contrast-enhanced computed tomography angiography (CTA).
Methods
Whole-heart 1.5 T MRA was performed in 33 patients (aged 84 years [IQR 79–86], 48% male) for aortic root sizing and measurements of coronary ostia heights. A subgroup of 18 (55%) patients underwent additional CTA as gold standard for TAVI measurements. Image quality was assessed by a 4-point Likert scale, continuous MRA and CTA measurements were compared with regression and Bland-Altman analysis, valve sizing by kappa statistics.
Results
Median image quality of MRA as rated by two observers according was 1.5 [IQR 1.5–2.5]. In 4 patients (12%) one coronary ostium each (right coronary artery 3, left main artery 1) was not clearly definable on MRA. Inter-observer correlation was substantial to excellent (r=0.61 to 0.92) with a bias of 19 mm2 for annulus area (lower limit of agreement −59 mm2, upper limit of agreement 98 mm2; p=0.009). Aortic root and ostia height measurements by MRA and CTA showed substantial to excellent correlation (r=0.65 to 0.90) with no significant bias (all p≥0.333). Mean annulus area for MRA was 414±71 mm2 and for CTA 422±80 mm2 (r=0.9) with a bias of −8 mm2 (lower limit of agreement −79 mm2, upper limit of agreement −62 mm2; p=0.333). Regarding prosthetic valve sizing there was complete consistency between MRA and CTA-based decisions (κ=1).
Conclusion
Self-navigated noncontrast 3D whole-heart MRA enables reliable aortic root TAVI measurements without significant difference to standardized CTA. Prosthesis sizing by MRA measurements would completely match to CTA-based choice. However, in some cases coronary ostia may be difficult to define.
Funding Acknowledgement
Type of funding source: None |
---|---|
ISSN: | 0195-668X 1522-9645 |
DOI: | 10.1093/ehjci/ehaa946.0304 |