Influence of lesion location on the accuracy of CT derived FFR: head-to-head comparison with invasive FFR

Abstract Background The accuracy of CT-derived FFR (FFRCT) has been repeatedly reported. However, the influence of lesion location on accuracy is unknown. Therefore, we evaluated the diagnostic accuracy of FFRCT to detect lesion-specific ischemia and determined the influence of lesion location (prox...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:European heart journal 2020-11, Vol.41 (Supplement_2)
Hauptverfasser: Moshage, M, Smolka, S, Achenbach, S, Ammon, F, Ferstl, P, Goeller, M, Bittner, D.O, Uehlein, S, Bal, Z, Marwan, M
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Abstract Background The accuracy of CT-derived FFR (FFRCT) has been repeatedly reported. However, the influence of lesion location on accuracy is unknown. Therefore, we evaluated the diagnostic accuracy of FFRCT to detect lesion-specific ischemia and determined the influence of lesion location (proximal vs. distal vessel segments) compared to invasively measured FFR in patients with suspected CAD. Methods A total of 136 vessels in which “Dual-Source”-CT coronary angiography had been performed due to suspected CAD and who were further referred for invasive coronary angiography with invasive FFR measurement within three months of the index CT examination were retrospectively identified and screened for inclusion in this analysis. Patients with either left main coronary artery stenoses, bifurcation or ostial stenoses were excluded. Invasive FFR was measured using a pressure wire (CERTUS®, St. Jude Medical, Minnesota, USA or Verrata®, Volcano, San Diego, USA). FFRCT was calculated using an on-site prototype (cFFR Version 3.0, Siemens Healthineers, Forchheim, Germany). All vessels were analyzed by an experienced observer blinded to the results of invasive FFR. Stenoses with invasively measured FFR ≤0.80 were classified as hemodynamically significant. We evaluated the diagnostic accuracy of FFRCT in proximal vs. non-proximal vessel segments. Proximal lesions included stenoses located in segment one, six, eleven and twelve. All other stenoses were categorized as distal lesions. Results Out of 136 coronary stenoses, 47 (35%) were located in proximal segments and 89 (65%) lesions were located in distal segments. Compared to invasive FFR, the sensitivity of FFRCT to correctly identify/exclude hemodynamically significant stenoses in proximal vessel segments was 93% (95% CI: 68–99.8%) and the specificity was 100% (95% CI: 89–100%), compared to a sensitivity of 72% (95% CI: 46.5–90%) and a specificity of 87% (95% CI: 77–94%) for FFRCT in distal lesions. The positive predictive value was 100% and the negative predictive value was 97% (95% CI: 82.8–99.5%) compared to a positive predictive value of 59% (95% CI: 42–93.9%) and a negative predictive value of 93% (95% CI: 85.4–96.3%) for proximal vs. distal vessel segment, respectively. This corresponds to an accuracy of 98% vs. 84%, respectively (p=0.02). ROC-Curve analysis showed a slightly higher – albeit non-significant – area under the curve for FFRCT to detect hemodynamic relevance in proximal lesions compared to distal
ISSN:0195-668X
1522-9645
DOI:10.1093/ehjci/ehaa946.0158