Multicenter evaluation of two chemiluminescence and three lateral flow immunoassays for the diagnosis of COVID-19 and assessment of antibody dynamic responses to SARS-CoV-2 in Taiwan

This multicenter, retrospective study included 346 serum samples from 74 patients with coronavirus disease 2019 (COVID-19) and 194 serum samples from non-COVID-19 patients to evaluate the performance of five anti-severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antibody tests, i.e. two c...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Emerging microbes & infections 2020-01, Vol.9 (1), p.2157-2168
Hauptverfasser: Chen, Shey-Ying, Lee, Yu-Lin, Lin, Yi-Chun, Lee, Nan-Yao, Liao, Chia-Hung, Hung, Yuan-Pin, Lu, Min-Chi, Wu, Jhong-Lin, Tseng, Wen-Pin, Lin, Chien-Hao, Chung, Ming-Yi, Kang, Chun-Min, Lee, Ya-Fan, Lee, Tai-Fen, Cheng, Chien-Yu, Chen, Cheng-Pin, Huang, Chien-Hua, Liu, Chun-Eng, Cheng, Shu-Hsing, Ko, Wen-Chien, Hsueh, Po-Ren, Chen, Shyr-Chyr
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This multicenter, retrospective study included 346 serum samples from 74 patients with coronavirus disease 2019 (COVID-19) and 194 serum samples from non-COVID-19 patients to evaluate the performance of five anti-severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antibody tests, i.e. two chemiluminescence immunoassays (CLIAs): Roche Elecsys® Anti-SARS-CoV-2 Test (Roche Test) and Abbott SARS-CoV-2 IgG (Abbott Test), and three lateral flow immunoassays (LFIAs): Wondfo SARS-CoV-2 Antibody Test (Wondfo Test), ASK COVID-19 IgG/IgM Rapid Test (ASK Test), and Dynamiker 2019-nCoV IgG/IgM Rapid Test (Dynamiker Test). We found high diagnostic sensitivities (%, 95% confidence interval [CI]) for the Roche Test (97.4%, 93.4-99.0%), Abbott Test (94.0%, 89.1-96.8%), Wondfo Test (91.4%, 85.8-94.9%), ASK Test (97.4%, 93.4-99.0%), and Dynamiker Test (90.1%, 84.3-94.0%) after >21 days of symptom onset. Meanwhile, the diagnostic specificity was 99.0% (95% CI, 96.3-99.7%) for the Roche Test, 97.9% (95% CI, 94.8-99.2%) for the Abbott Test, and 100.0% (95% CI, 98.1-100.0%) for the three LFIAs. Cross-reactivity was observed in sera containing anti-cytomegalovirus (CMV) IgG/IgM antibodies and autoantibodies. No difference was observed in the time to seroconversion detection of the five serological tests. Specimens from patients with COVID-19 pneumonia demonstrated a shorter seroconversion time and higher chemiluminescent signal than those without pneumonia. Our data suggested that understanding the dynamic antibody response after COVID-19 infection and performance characteristics of different serological test are crucial for the appropriate interpretation of serological test result for the diagnosis and risk assessment of patient with COVID-19 infection.
ISSN:2222-1751