High-Temperature Low-Cycle Fatigue Tests on Hastelloy X

Tensile and low cycle fatigue tests were conducted on Hastelloy X in vacuum at several temperatures from room temperature to 900°C. The mid-range ductility minimum generally observed in nickel-base superalloys did not show itself in the material containing yttrium and which was solution heat treated...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of nuclear science and technology 1977-05, Vol.14 (5), p.381-386
Hauptverfasser: SUZUKI, Hiroshige, ISEKI, Takayoshi, SHODA, Yoshio
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Tensile and low cycle fatigue tests were conducted on Hastelloy X in vacuum at several temperatures from room temperature to 900°C. The mid-range ductility minimum generally observed in nickel-base superalloys did not show itself in the material containing yttrium and which was solution heat treated at a higher temperature. The fatigue crack growth rate was calculated from the measured intervals of fatigue striation observed by scanning electron microscopy. The specimen that was fractured at 900°C did not present the typical fatigue surface, and instead the rupture was characterized by marked reduction in area and a large cavity in the center of the fracture.
ISSN:0022-3131
1881-1248
DOI:10.1080/18811248.1977.9730773