Improved Steady State and Transient Performance With Optimum Excitation of Single-Phase Self-Excited Induction Generator

This article deals with the performance prediction and analysis of the two winding single-phase self-excited induction generator (single-phase SEIG). A methodology of selection of capacitors for optimum excitation of the single-phase SEIG scheme is explained. Appropriate dynamic model of the system...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Electric machines and power systems 2000-07, Vol.28 (7), p.591-604
1. Verfasser: Singh, L. B. Shilpakar, S. S. Murthy, A. K. Tiwari, Bhim
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This article deals with the performance prediction and analysis of the two winding single-phase self-excited induction generator (single-phase SEIG). A methodology of selection of capacitors for optimum excitation of the single-phase SEIG scheme is explained. Appropriate dynamic model of the system is developed incorporating the cross-saturation effect. This dynamic model is used for simulating realistic transients, such as no-load and on-load excitation, load perturbation, short-circuit condition, and re-excitation. Simulation results are confirmed by experimental investigation, thus providing verification of the derived model. The results are analyzed to obtain useful guidelines toward system improvements under such transients.
ISSN:0731-356X