PERFORMANCE LIMITS IN GRAVITY-ASSISTED HYDROGEN HEAT PIPES

Small diameter, gravity-assisted, hydrogen heat pipes were fabricated and tested with performance limits as a function of tilt angle and working fluid inventory reported. The fabrication method, the filling sequence, and the test procedure are also described. Results are compared with the flooding l...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Chemical engineering communications 1989-11, Vol.85 (1), p.157-167
Hauptverfasser: HILL, D.D., PRENGER, F.C., BARCLAY, J.A.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Small diameter, gravity-assisted, hydrogen heat pipes were fabricated and tested with performance limits as a function of tilt angle and working fluid inventory reported. The fabrication method, the filling sequence, and the test procedure are also described. Results are compared with the flooding limit model and operating characteristics of the heat pipe are then discussed. The heat pipe operated over a large fraction of the triple point to critical point domain of the working fluid.
ISSN:0098-6445
1563-5201
DOI:10.1080/00986448908940353