The hybrid personal cooling system (PCS) could effectively reduce the heat strain while exercising in a hot and moderate humid environment
This study aimed to examine the effectiveness of a hybrid personal cooling system (PCS) in mitigating body heat stain while exercising in a hot environment. Eight subjects underwent two trials: PCS and CON (i.e. no cooling). All trials were conducted at an air temperature of 36 ± 0.5 °C and RH = 59 ...
Gespeichert in:
Veröffentlicht in: | Ergonomics 2016-08, Vol.59 (8), p.1009-1018 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | This study aimed to examine the effectiveness of a hybrid personal cooling system (PCS) in mitigating body heat stain while exercising in a hot environment. Eight subjects underwent two trials: PCS and CON (i.e. no cooling). All trials were conducted at an air temperature of 36 ± 0.5 °C and RH = 59 ± 5%. The key findings demonstrated that the PCS could significantly reduce the core temperature, mean skin temperature, heart rate and physiological strain index during both exercise and recovery periods (p |
---|---|
ISSN: | 0014-0139 1366-5847 |