Comparison of Time-Resolved and -Unresolved Measurements of Deoxyhemoglobin in Brain
Continuous (CW) and pulsed light were used for the noninvasive measurement of hemoglobin oxygenation in tissues. A dual wavelength method of continuous illumination spectroscopy used 760 nm (deoxyhemoglobin peak) and 800 nm (an oxyhemoglobin-deoxyhemoglobin isosbestic point) to measure the kinetics...
Gespeichert in:
Veröffentlicht in: | Proceedings of the National Academy of Sciences - PNAS 1988-07, Vol.85 (14), p.4971-4975 |
---|---|
Hauptverfasser: | , , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Continuous (CW) and pulsed light were used for the noninvasive measurement of hemoglobin oxygenation in tissues. A dual wavelength method of continuous illumination spectroscopy used 760 nm (deoxyhemoglobin peak) and 800 nm (an oxyhemoglobin-deoxyhemoglobin isosbestic point) to measure the kinetics and extent of oxyhemoglobin deoxygenation in brains during mild ischemia/hypoxia. Absorption and scattering were modeled in an artificial milk/yeast blood system, which gave an exponential relationship between absorption and optical path length to a depth of 7 cm. Time-resolved spectroscopy (10-ps resolution) afforded a display of the times and distances of arrival of photons emitted by the cat brain in response to a 10-ps input pulse. The emitted photons rose to a peak in a fraction of a nanosecond and declined exponentially over a few nanoseconds. The half-time of exponential decay corresponds to photon migration over a distance of 4 cm. Exponential light emission continued for several more nanoseconds when the brain was encased by the skull, which plays a key role in prolonging light emission. The exponential decline of light intensity has a value [exp(-μ L)], where L is the path length determined from the time/distance scale and μ is the characteristic of the migration of light in the brain. The factor μ is increased by increasing absorption, and μ ′ = ε C where ε and C are the Beer-Lambert parameters of extinction coefficient (ε ) and concentration (C). Thus, deoxyhemoglobin can be quantified in brain tissues. |
---|---|
ISSN: | 0027-8424 1091-6490 |
DOI: | 10.1073/pnas.85.14.4971 |