Project Aquarius 4. Experimental Bushfires, Suppression Procedures, and Measurements
Experimental bushfires were lit over three summers in Australian eucalypt forests with fuel loads (mean and range) of 11.3 (8-14) tonnes per hectare, in air temperature 25 (17-33)° C, relative humidity 47 (14-81)%, and wind speed 4.4 (2-9) m s -1 . The McArthur Forest Fire Danger Index (FFDI) ranged...
Gespeichert in:
Veröffentlicht in: | International journal of wildland fire 1997, Vol.7 (2), p.99-104 |
---|---|
Hauptverfasser: | , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Experimental bushfires were lit over three summers in Australian eucalypt forests with fuel loads (mean and range) of 11.3 (8-14) tonnes per hectare, in air temperature 25 (17-33)° C, relative humidity 47 (14-81)%, and wind speed 4.4 (2-9) m s -1 . The McArthur Forest Fire Danger Index (FFDI) ranged from 2 to 18 and was evenly distributed between 'low', 'moderate', and 'high' fire dangers. Fires were lit on a crosswind ignition line of 50-200 metres, and were allowed to develop for 10-50 minutes before a seven-man hand-tool crew commenced its attack. Airborne infra-red imagery showed that head-fire intensity (averaged over 6 minutes) of most fires exceeded 1000 kW per metre of fire front (kW m -1 ) at some stage and ranged as high as 3280 kW m -1 , challenging the crew in much the same way as summer wildfires and evoking similar uncertainty and apprehension. Firefighters were generally unable to suppress headfires with an intensity of more than 1000 kW m -1 . Comprehensive measurements were made of the stresses the firefighters and scientific observers experienced, their physiological and subjective responses, and the firefighters' productivity and efficiency. In all, 23 km of fireline were constructed and 238 man-days of measurements were obtained — 179 on the firefighters, 59 on the scientists. Keywords: Australian forest fires; wildland fiues; fiuefighting; fue suppression; hand tools; limits of suppression with hand tools; fuel loads, rate of spread; fue intensity; airborne infra-red imagery; McArthur Forest Fire Danger Index (FFDI) International Journal of Wildland Fire 7(2) 99 - 104 Full text doi:10.1071/WF9970099 © CSIRO 1997 |
---|---|
ISSN: | 1049-8001 1448-5516 |
DOI: | 10.1071/WF9970099 |