A quick assay for monitoring recombinant hirudin during cardiopulmonary bypass in patients with heparin-induced thrombocytopenia type IIAdaptation of the ecarin clotting time to the Act II device
Background: Recombinant hirudin is increasingly advocated as a promising alternative anticoagulation for patients with heparin-induced thrombocytopenia type II during cardiopulmonary bypass. This requires monitoring of the ecarin clotting time. No commercial ecarin clotting time assay is available f...
Gespeichert in:
Veröffentlicht in: | The Journal of thoracic and cardiovascular surgery 2000-06, Vol.119 (6), p.1278-1283 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Background: Recombinant hirudin is increasingly advocated as a promising alternative anticoagulation for patients with heparin-induced thrombocytopenia type II during cardiopulmonary bypass. This requires monitoring of the ecarin clotting time. No commercial ecarin clotting time assay is available for clinical use. We adapted the ecarin clotting time to the easy-to-handle ACT II device.
Methods: Three different concentrations of the ecarin reagent (20, 10, 5 U/mL) were investigated as preliminary studies. Standard calibration curves were constructed for concentrations of recombinant hirudin ranging from 0 to 5 μg/mL. In vivo samples were collected from patients with heparin-induced thrombocytopenia type II who underwent cardiopulmonary bypass, and the values were compared with the values obtained by the chromogenic method. The final concentration for the assay of 5 IU/mL ecarin was further assessed in vitro for reproducibility and the influence of variations in hematocrit, platelet count, and procoagulants.
Results: All three concentrations of ecarin revealed linearity to 5 μg/mL concentrations of recombinant hirudin. The ecarin concentration of 5 U/mL revealed the best correlation (0.87) to the laboratory method, was reproducible over the whole recombinant hirudin range, and was not influenced by the variations in the in vitro setup.
Conclusions: The ACT II/ecarin clotting time with an ecarin concentration of 5 U/mL is a simple and reliable assay for monitoring recombinant hirudin during cardiopulmonary bypass. Use of this assay allows a wider use of recombinant hirudin in patients with heparin-induced thrombocytopenia type II during bypass and thereby may contribute to the safer management of these patients. (J Thorac Cardiovasc Surg 2000;119:1278-83) |
---|---|
ISSN: | 0022-5223 1097-685X |
DOI: | 10.1067/mtc.2000.106088 |