Rate constants for deactivation of N2( A 3Σ+u, v ′ = 0,1) by O
The removal of N2(A 3Σ+u, v′ = 0,1) by O has been studied in a room temperature discharge–flow apparatus by monitoring the temporal decay of the 0,6 and 1,10 bands of the Vegard–Kaplan system. The measured rate constants are (2.8±0.4) and (3.4±0.6)×10−11 cm3 molecule−1 s−1 for v′ = 0 and 1, respect...
Gespeichert in:
Veröffentlicht in: | The Journal of chemical physics 1981-09, Vol.75 (6), p.2847-2852 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The removal of N2(A 3Σ+u, v′ = 0,1) by O has been studied in a room temperature discharge–flow apparatus by monitoring the temporal decay of the 0,6 and 1,10 bands of the Vegard–Kaplan system. The measured rate constants are (2.8±0.4) and (3.4±0.6)×10−11 cm3 molecule−1 s−1 for v′ = 0 and 1, respectively. |
---|---|
ISSN: | 0021-9606 1089-7690 |
DOI: | 10.1063/1.442357 |