Dielectric breakdown of MgO magnetic tunnel junctions

We have investigated high-quality MgO tunnel junctions with a range of barrier thickness in order to identify the underlying physical mechanism responsible for dielectric breakdown. Two types of dielectric breakdown ("soft" and "hard") were observed. Soft breakdown was observed i...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Applied physics letters 2009-03, Vol.94 (12), p.123110-123110-3
Hauptverfasser: Dimitrov, D. V., Gao, Zheng, Wang, Xiaobin, Jung, Wonjoon, Lou, Xiaohua, Heinonen, Olle G.
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:We have investigated high-quality MgO tunnel junctions with a range of barrier thickness in order to identify the underlying physical mechanism responsible for dielectric breakdown. Two types of dielectric breakdown ("soft" and "hard") were observed. Soft breakdown was observed in a few percent of the devices. This breakdown mode is not intrinsic and is attributed to tunnel junction imperfections. The hard breakdown occurs because a critical electric field is reached across the tunnel barrier. Other possible breakdown mechanisms, such as thermally driven mass diffusion or charge trapping, were not consistent with the hard dielectric breakdown data and were ruled out.
ISSN:0003-6951
1077-3118
DOI:10.1063/1.3109792