Linear magnetic flux amplifier

By measuring the critical current versus the applied magnetic field I c ( Φ ) of an Al superconducting loop enclosing a soft Permalloy magnetic dot, we demonstrate that it is feasible to design a linear magnetic flux amplifier for applications in superconducting quantum interference devices. The sel...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Applied physics letters 2005-10, Vol.87 (14), p.142501-142501-3
Hauptverfasser: Golubović, D. S., Moshchalkov, V. V.
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:By measuring the critical current versus the applied magnetic field I c ( Φ ) of an Al superconducting loop enclosing a soft Permalloy magnetic dot, we demonstrate that it is feasible to design a linear magnetic flux amplifier for applications in superconducting quantum interference devices. The selected dimensions of a single-domain Permalloy dot provide that the preferential orientation of the magnetization is rotated from the perpendicular direction. By increasing an applied magnetic field, the magnetization of the dot coherently rotates toward the out-of-plane direction, thus providing a flux gain and an enhancement of the sensitivity. As a result of a pronounced shape anisotropy, the flux gain generated by the dot can be tuned by adjusting the dimensions of the dot.