A Fringe Counting Laser Interferometer Manometer
A prototype standard mercury manometer using a fringe counting laser interferometer to measure the differential height of the mercury columns has been built and successfully operated. The 10.6 μ wavelength radiation from a CO2 laser and specially treated manometer tubes have been used to reduce the...
Gespeichert in:
Veröffentlicht in: | Review of scientific instruments 1973-02, Vol.44 (2), p.180-182 |
---|---|
1. Verfasser: | |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A prototype standard mercury manometer using a fringe counting laser interferometer to measure the differential height of the mercury columns has been built and successfully operated. The 10.6 μ wavelength radiation from a CO2 laser and specially treated manometer tubes have been used to reduce the effect of disturbances on the mercury surface so that reliable operation of the manometer is possible. |
---|---|
ISSN: | 0034-6748 1089-7623 |
DOI: | 10.1063/1.1686077 |