Ion-cut silicon-on-insulator fabrication with plasma immersion ion implantation
We report the implementation of ion-cut silicon-on-insulator (SOI) wafer fabrication technique with plasma immersion ion implantation (PIII). The hydrogen implantation rate, which is independent of the wafer size, is considerably higher than that of conventional implantation. The simple PIII reactor...
Gespeichert in:
Veröffentlicht in: | Applied physics letters 1997-11, Vol.71 (19), p.2767-2769 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | We report the implementation of ion-cut silicon-on-insulator (SOI) wafer fabrication technique with plasma immersion ion implantation (PIII). The hydrogen implantation rate, which is independent of the wafer size, is considerably higher than that of conventional implantation. The simple PIII reactor setup and its compatibility with cluster-tools offer other ion-cut process optimization opportunities. The feasibility of the PIII ion-cut process is demonstrated by successful fabrication of SOI structures. The hydrogen plasma can be optimized so that only one ion species is dominant. The feasibility of performing ion-cut using helium PIII is also demonstrated. |
---|---|
ISSN: | 0003-6951 1077-3118 |
DOI: | 10.1063/1.120127 |