A multichannel ion mass spectrometer in laser‐produced plasma studies
The theory and operation of a time‐of‐flight mass spectrometer employing a multichannel electrostatic analyzer are discussed with emphasis placed on laser‐produced plasma studies. It is shown that the finite length of the analyzer leads to enhanced mass resolution. A method of i n s i t u calibratio...
Gespeichert in:
Veröffentlicht in: | Rev. Sci. Instrum.; (United States) 1976-05, Vol.47 (5), p.548-552 |
---|---|
1. Verfasser: | |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 552 |
---|---|
container_issue | 5 |
container_start_page | 548 |
container_title | Rev. Sci. Instrum.; (United States) |
container_volume | 47 |
creator | Goforth, R. R. |
description | The theory and operation of a time‐of‐flight mass spectrometer employing a multichannel electrostatic analyzer are discussed with emphasis placed on laser‐produced plasma studies. It is shown that the finite length of the analyzer leads to enhanced mass resolution. A method of i
n
s
i
t
u calibration of the analyzer channels is described, and measurements of the resolution and beam divergence are presented. Use of the mass spectrometer to calibrate ion‐collecting probes for mass and kinetic energy measurements is also considered. |
doi_str_mv | 10.1063/1.1134688 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1063_1_1134688</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>22610224</sourcerecordid><originalsourceid>FETCH-LOGICAL-c355t-301d6963effbf0917f3164dd9c81a13243c01cead7702b3519f7ff84425f0f443</originalsourceid><addsrcrecordid>eNp90M1KAzEQB_AgCtbqwTcIHgSF1UySze4eS9EqFLzoOaT5oJH9MskK3nwEn9EncWuLHgTnMjD8mBn-CJ0CuQIi2DVcATAuynIPTYCUVVYIyvbRhBDGM1Hw8hAdxfhMxsoBJmgxw81QJ6_Xqm1tjX3X4kbFiGNvdQpdY5MN2Le4VtGGz_ePPnRm0Nbgfpw0Csc0GG_jMTpwqo72ZNen6On25nF-ly0fFvfz2TLTLM9TxggYUQlmnVs5UkHhGAhuTKVLUMAoZ5qAtsoUBaErlkPlCudKzmnuiOOcTdHZdm8Xk5dR-2T1Wnfj7zrJgglefaPzLRqffRlsTLLxUdu6Vq3thigpFUAo3cCLLdShizFYJ_vgGxXeJBC5yVOC3OU52sut3RxVaQzqB7924RfK3rj_8N_NXwIGg-I</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>22610224</pqid></control><display><type>article</type><title>A multichannel ion mass spectrometer in laser‐produced plasma studies</title><source>AIP Digital Archive</source><creator>Goforth, R. R.</creator><creatorcontrib>Goforth, R. R. ; KMS Fusion, Incorporated, Ann Arbor, Michigan 48104</creatorcontrib><description>The theory and operation of a time‐of‐flight mass spectrometer employing a multichannel electrostatic analyzer are discussed with emphasis placed on laser‐produced plasma studies. It is shown that the finite length of the analyzer leads to enhanced mass resolution. A method of i
n
s
i
t
u calibration of the analyzer channels is described, and measurements of the resolution and beam divergence are presented. Use of the mass spectrometer to calibrate ion‐collecting probes for mass and kinetic energy measurements is also considered.</description><identifier>ISSN: 0034-6748</identifier><identifier>EISSN: 1089-7623</identifier><identifier>DOI: 10.1063/1.1134688</identifier><identifier>CODEN: RSINAK</identifier><language>eng</language><publisher>United States</publisher><subject>70 PLASMA PHYSICS AND FUSION TECHNOLOGY ; 700102 - Fusion Energy- Plasma Research- Diagnostics ; CALIBRATION ; ELECTRONIC EQUIPMENT ; ENERGY ; KINETIC ENERGY ; LASER-PRODUCED PLASMA ; MASS RESOLUTION ; MASS SPECTRA ; MASS SPECTROMETERS ; MEASURING INSTRUMENTS ; MULTI-CHANNEL ANALYZERS ; PLASMA ; PLASMA DIAGNOSTICS ; PULSE ANALYZERS ; RESOLUTION ; SPECTRA ; SPECTROMETERS</subject><ispartof>Rev. Sci. Instrum.; (United States), 1976-05, Vol.47 (5), p.548-552</ispartof><rights>American Institute of Physics</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c355t-301d6963effbf0917f3164dd9c81a13243c01cead7702b3519f7ff84425f0f443</citedby><cites>FETCH-LOGICAL-c355t-301d6963effbf0917f3164dd9c81a13243c01cead7702b3519f7ff84425f0f443</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://pubs.aip.org/rsi/article-lookup/doi/10.1063/1.1134688$$EHTML$$P50$$Gscitation$$H</linktohtml><link.rule.ids>314,776,780,881,1553,27901,27902,76133</link.rule.ids><backlink>$$Uhttps://www.osti.gov/biblio/7364944$$D View this record in Osti.gov$$Hfree_for_read</backlink></links><search><creatorcontrib>Goforth, R. R.</creatorcontrib><creatorcontrib>KMS Fusion, Incorporated, Ann Arbor, Michigan 48104</creatorcontrib><title>A multichannel ion mass spectrometer in laser‐produced plasma studies</title><title>Rev. Sci. Instrum.; (United States)</title><description>The theory and operation of a time‐of‐flight mass spectrometer employing a multichannel electrostatic analyzer are discussed with emphasis placed on laser‐produced plasma studies. It is shown that the finite length of the analyzer leads to enhanced mass resolution. A method of i
n
s
i
t
u calibration of the analyzer channels is described, and measurements of the resolution and beam divergence are presented. Use of the mass spectrometer to calibrate ion‐collecting probes for mass and kinetic energy measurements is also considered.</description><subject>70 PLASMA PHYSICS AND FUSION TECHNOLOGY</subject><subject>700102 - Fusion Energy- Plasma Research- Diagnostics</subject><subject>CALIBRATION</subject><subject>ELECTRONIC EQUIPMENT</subject><subject>ENERGY</subject><subject>KINETIC ENERGY</subject><subject>LASER-PRODUCED PLASMA</subject><subject>MASS RESOLUTION</subject><subject>MASS SPECTRA</subject><subject>MASS SPECTROMETERS</subject><subject>MEASURING INSTRUMENTS</subject><subject>MULTI-CHANNEL ANALYZERS</subject><subject>PLASMA</subject><subject>PLASMA DIAGNOSTICS</subject><subject>PULSE ANALYZERS</subject><subject>RESOLUTION</subject><subject>SPECTRA</subject><subject>SPECTROMETERS</subject><issn>0034-6748</issn><issn>1089-7623</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1976</creationdate><recordtype>article</recordtype><recordid>eNp90M1KAzEQB_AgCtbqwTcIHgSF1UySze4eS9EqFLzoOaT5oJH9MskK3nwEn9EncWuLHgTnMjD8mBn-CJ0CuQIi2DVcATAuynIPTYCUVVYIyvbRhBDGM1Hw8hAdxfhMxsoBJmgxw81QJ6_Xqm1tjX3X4kbFiGNvdQpdY5MN2Le4VtGGz_ePPnRm0Nbgfpw0Csc0GG_jMTpwqo72ZNen6On25nF-ly0fFvfz2TLTLM9TxggYUQlmnVs5UkHhGAhuTKVLUMAoZ5qAtsoUBaErlkPlCudKzmnuiOOcTdHZdm8Xk5dR-2T1Wnfj7zrJgglefaPzLRqffRlsTLLxUdu6Vq3thigpFUAo3cCLLdShizFYJ_vgGxXeJBC5yVOC3OU52sut3RxVaQzqB7924RfK3rj_8N_NXwIGg-I</recordid><startdate>197605</startdate><enddate>197605</enddate><creator>Goforth, R. R.</creator><scope>AAYXX</scope><scope>CITATION</scope><scope>8FD</scope><scope>H8D</scope><scope>L7M</scope><scope>OTOTI</scope></search><sort><creationdate>197605</creationdate><title>A multichannel ion mass spectrometer in laser‐produced plasma studies</title><author>Goforth, R. R.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c355t-301d6963effbf0917f3164dd9c81a13243c01cead7702b3519f7ff84425f0f443</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1976</creationdate><topic>70 PLASMA PHYSICS AND FUSION TECHNOLOGY</topic><topic>700102 - Fusion Energy- Plasma Research- Diagnostics</topic><topic>CALIBRATION</topic><topic>ELECTRONIC EQUIPMENT</topic><topic>ENERGY</topic><topic>KINETIC ENERGY</topic><topic>LASER-PRODUCED PLASMA</topic><topic>MASS RESOLUTION</topic><topic>MASS SPECTRA</topic><topic>MASS SPECTROMETERS</topic><topic>MEASURING INSTRUMENTS</topic><topic>MULTI-CHANNEL ANALYZERS</topic><topic>PLASMA</topic><topic>PLASMA DIAGNOSTICS</topic><topic>PULSE ANALYZERS</topic><topic>RESOLUTION</topic><topic>SPECTRA</topic><topic>SPECTROMETERS</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Goforth, R. R.</creatorcontrib><creatorcontrib>KMS Fusion, Incorporated, Ann Arbor, Michigan 48104</creatorcontrib><collection>CrossRef</collection><collection>Technology Research Database</collection><collection>Aerospace Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>OSTI.GOV</collection><jtitle>Rev. Sci. Instrum.; (United States)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Goforth, R. R.</au><aucorp>KMS Fusion, Incorporated, Ann Arbor, Michigan 48104</aucorp><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A multichannel ion mass spectrometer in laser‐produced plasma studies</atitle><jtitle>Rev. Sci. Instrum.; (United States)</jtitle><date>1976-05</date><risdate>1976</risdate><volume>47</volume><issue>5</issue><spage>548</spage><epage>552</epage><pages>548-552</pages><issn>0034-6748</issn><eissn>1089-7623</eissn><coden>RSINAK</coden><abstract>The theory and operation of a time‐of‐flight mass spectrometer employing a multichannel electrostatic analyzer are discussed with emphasis placed on laser‐produced plasma studies. It is shown that the finite length of the analyzer leads to enhanced mass resolution. A method of i
n
s
i
t
u calibration of the analyzer channels is described, and measurements of the resolution and beam divergence are presented. Use of the mass spectrometer to calibrate ion‐collecting probes for mass and kinetic energy measurements is also considered.</abstract><cop>United States</cop><doi>10.1063/1.1134688</doi><tpages>5</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0034-6748 |
ispartof | Rev. Sci. Instrum.; (United States), 1976-05, Vol.47 (5), p.548-552 |
issn | 0034-6748 1089-7623 |
language | eng |
recordid | cdi_crossref_primary_10_1063_1_1134688 |
source | AIP Digital Archive |
subjects | 70 PLASMA PHYSICS AND FUSION TECHNOLOGY 700102 - Fusion Energy- Plasma Research- Diagnostics CALIBRATION ELECTRONIC EQUIPMENT ENERGY KINETIC ENERGY LASER-PRODUCED PLASMA MASS RESOLUTION MASS SPECTRA MASS SPECTROMETERS MEASURING INSTRUMENTS MULTI-CHANNEL ANALYZERS PLASMA PLASMA DIAGNOSTICS PULSE ANALYZERS RESOLUTION SPECTRA SPECTROMETERS |
title | A multichannel ion mass spectrometer in laser‐produced plasma studies |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-30T04%3A03%3A34IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20multichannel%20ion%20mass%20spectrometer%20in%20laser%E2%80%90produced%20plasma%20studies&rft.jtitle=Rev.%20Sci.%20Instrum.;%20(United%20States)&rft.au=Goforth,%20R.%20R.&rft.aucorp=KMS%20Fusion,%20Incorporated,%20Ann%20Arbor,%20Michigan%2048104&rft.date=1976-05&rft.volume=47&rft.issue=5&rft.spage=548&rft.epage=552&rft.pages=548-552&rft.issn=0034-6748&rft.eissn=1089-7623&rft.coden=RSINAK&rft_id=info:doi/10.1063/1.1134688&rft_dat=%3Cproquest_cross%3E22610224%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=22610224&rft_id=info:pmid/&rfr_iscdi=true |