Application of Double-Threaded Locking Adaptation Plates used to Repair a Radius and Ulna Fracture in a Domestic Rabbit (Oryctolagus Cuniculus)
Abstract Objective This study is a case description of the clinical application of locking plates to repair fractures in the radius and ulna of a 9-month-old, male domestic rabbit. Study Design This study is a case report. Results Double-threaded locking adaptation plates of 1.5 mm were fixated t...
Gespeichert in:
Veröffentlicht in: | VCOT Open 2020-07, Vol.3 (2), p.e182-e186 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Abstract
Objective
This study is a case description of the clinical application of locking plates to repair fractures in the radius and ulna of a 9-month-old, male domestic rabbit.
Study Design
This study is a case report.
Results
Double-threaded locking adaptation plates of 1.5 mm were fixated to the radius and ulna of the rabbit using the principles of orthogonal plating. Radiographs of the left radius and ulna were obtained at 8 weeks postoperatively depicting complete osseous union of the fracture and no implant complications were observed.
Clinical Significance
The authors describe the first clinical report of 1.5 mm locking adaptation plates having been used in repairing radius and ulna fractures in a domestic rabbit. |
---|---|