New extraction method of THC and its metabolites, 11-OH-THC and THC-COOH, in plasma
Objectives: A liquid/liquid extraction technique on solid support of Δ9-tetradydrocannabinol (THC), 11-hydroxy-Δ9-tetradydrocannabinol (11-OH-THC) and 11-nor-Δ9-tetradydrocannabinol-9-carboxylic acid (THC-COOH) in plasma was developed in order to be assayed by high-performance liquid chromatography...
Gespeichert in:
Veröffentlicht in: | Annales de toxicologie analytique 2013, Vol.25 (1), p.1-5 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Objectives: A liquid/liquid extraction technique on solid support of Δ9-tetradydrocannabinol (THC), 11-hydroxy-Δ9-tetradydrocannabinol (11-OH-THC) and 11-nor-Δ9-tetradydrocannabinol-9-carboxylic acid (THC-COOH) in plasma was developed in order to be assayed by high-performance liquid chromatography and tandem mass spectrometry (HPLC-MS/MS). Methods: The samples were extracted by liquid/liquid extraction over solid support of an extraction cartridge. The extracts were thereafter dried down and injected into the HPLC-MS/MS system set with a positive electrospray mode using a Waters XTerra MS C18 3.5-μm 2.1 × 150 mm column. Results: The extraction recovery levels were 66%, 70% and 71% for THC, and 75%, 93% and 101% for 11-OH-THC at concentrations of 2.5, 5 and 10 ng/mL, respectively. They were 86% and 78% for THC-COOH at concentrations of 5 and 10 ng/mL. The limits of detection (LOD) were 0.09, 0.08 and 0.91 ng/mL for THC, 11-OH-THC and THC-COOH, respectively. The limits of quantification (LOQ) were 0.16, 0.15 and 3.24 ng/mL for THC, 11-OH-THC and THC-COOH, respectively. The inter-series incertitude CV determined for concentrations of 1, 2.5 and 10 ng/mL were 12.1%, 12.0% and 6.4% for THC, 14.5%, 11.1% and 7.2% for 11-OH-THC, and 14.9%, 26.2% and 11.3% for THC-COOH. Conclusion: The novel extraction method for THC, 11-OH-THC and THC-COOH developed in this work is rapid, sensitive and specific. It may be a valuable tool for predictive toxicology, high-throughput metabolism and pharmacokinetic studies of cannabinoids.
Objectifs : Une technique d’extraction liquide/liquide sur support solide du Δ9-tetradydrocannabinol (THC), 11-hydroxy-Δ9-tetradydrocannabinol (11-OH-THC) et de l’acide 11-nor-Δ9-tetradydrocannabinol-9-carboxylique (THC-COOH) dans le plasma est développée afin d’être dosés par chromatographie liquide haute pression couplée à une spectrométrie de masse en tandem (HPLC-MS/MS). Méthodes : L’échantillon est extrait par extraction liquide/liquide sur support solide, puis séché et injecté dans le système HPLC-MS/MS en mode electrospray positif et sur une colonne Waters XTERRA MS C18 3,5 μm 2,1 × 150 mm. Résultats : Les rendements d’extraction sont de 66 %, 70 % et 71 % pour le THC, 75 %, 93 % et 101 % pour le 11-OH-THC aux concentrations de 2,5, 5 et 10 ng/mL et de 86 % et 78 % pour le THC-COOH aux concentrations de 5 et 10 ng/mL. Les limites de détection (LOD) sont de 0.09 ng/mL pour le THC, 0,08 ng/mL pour le 11-OH-THC et 0,91 ng/mL pour le THC-COOH. L |
---|---|
ISSN: | 0768-598X 1961-9480 |
DOI: | 10.1051/ata/2013029 |