Characteristics of liquid electrode plasma for atomic emission spectrometry

Liquid electrode plasma atomic emission spectrometry (LEP-AES) is a recently developed elemental analysis method that uses microplasma. LEP forms in a vapor bubble generated inside a narrow-center microchannel by using high-voltage DC pulse power. We studied the characteristics of LEP and atomic emi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of analytical atomic spectrometry 2012-01, Vol.27 (9), p.1457-1464
Hauptverfasser: Kohara, Yoshinobu, Terui, Yasushi, Ichikawa, Megumi, Shirasaki, Toshihiro, Yamamoto, Kazuko, Yamamoto, Tamotsu, Takamura, Yuzuru
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Liquid electrode plasma atomic emission spectrometry (LEP-AES) is a recently developed elemental analysis method that uses microplasma. LEP forms in a vapor bubble generated inside a narrow-center microchannel by using high-voltage DC pulse power. We studied the characteristics of LEP and atomic emission of lead (Pb), as an example element, which has not been described in detail. We estimated the plasma parameters and observed the expansion and shrinkage of a vapor bubble with discharge as well as the time course and spatial distribution of the atomic emission of Pb (405.78 nm). The applied voltage was 2.5 kV and the pulse width was less than 3 ms, which produced a current of about 100 mA. We found that the excitation temperature was about 8000 K and the electron density was about 1 × 10 15 cm 3 . We also found that two quite different emission phases occurred separately during the time course. The first emission phase corresponds to the first expansion and shrinking of the bubble around atmospheric pressure and the second emission phase corresponds to the re-expansion of the bubble and emission at reduced pressure with higher atomic and lower background emissions. Maximum atomic and background emissions were observed at the narrowed center of the microchannel, but there was an additional local maximum atomic emission region at the anode side bubble-liquid interface where the background emission was very low, which would be a better condition for sensitive measurement. The limit of detection determined in our experiment was 4.0 g L 1 for Pb. Liquid electrode plasma atomic emission spectrometry (LEP-AES) is a recently developed elemental analysis method that uses microplasma in a vapor bubble generated inside a narrow-center microchannel by using high-voltage DC pulse power.
ISSN:0267-9477
1364-5544
DOI:10.1039/c2ja30023k