One-pot synthesis of a recyclable ratiometric fluorescent probe based on MOFs for turn-on sensing of Mg 2+ ions and bioimaging in live cells
A novel recyclable ratiometric fluorescent probe based on MOFs was designed and synthesized by a one-step approach, which was realized by assembling Al-MOFs in an aqueous solution containing rhodamine B (RhB) as a fluorescent reagent and Fe 3 O 4 as a magnetically recyclable reagent. The obtained fl...
Gespeichert in:
Veröffentlicht in: | New journal of chemistry 2019-11, Vol.43 (46), p.18377-18383 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A novel recyclable ratiometric fluorescent probe based on MOFs was designed and synthesized by a one-step approach, which was realized by assembling Al-MOFs in an aqueous solution containing rhodamine B (RhB) as a fluorescent reagent and Fe
3
O
4
as a magnetically recyclable reagent. The obtained fluorescent probe (Fe
3
O
4
/RhB@Al-MOFs) has two emissions under excitation at 330 nm, in which the emission at 440 nm is attributed to the Al-MOFs and the emission at 610 nm presumably originates from the RhB dye. It was noted that the probe displays responses to Mg
2+
ions with fluorescence enhancement at 440 nm, whereas the fluorescence at 610 nm would be a constant reference fluorescence signal. The existence of RhB significantly improves the detection accuracy and broadens the linear range. As a result, the selectivity of Fe
3
O
4
/RhB@Al-MOFs towards Mg
2+
compared to other metal ions is excellent. When the Mg
2+
ions (262.5 ppm) are added, the ratio of fluorescence intensity (
I
440
/
I
610
) is changed from 2.47 to 11.5. The Fe
3
O
4
/RhB@Al-MOFs show a rapid detection process (90 s), high fluorescence enhancement (up to 5-fold) and a low detection limit of Mg
2+
ions (8 × 10
−7
M). In particular, the magnetic Fe
3
O
4
endows Fe
3
O
4
/RhB@Al-MOFs with a high magnetic responsiveness, thus, facilitating the separation procedures. As expected, it can be easily separated and recycled without a significant loss of recognition performance after being used many times, and thus, exhibits good reusability. Meanwhile, the cell cytotoxicity experiments suggest that Fe
3
O
4
/RhB@Al-MOFs is nearly non-toxic and
in vitro
cell imaging experiments demonstrate that the probe is capable of successfully enhancing fluorescence from the intracellular area in HL-7702 and A375 cellular systems. Hence, it has the potential for the detection of Mg
2+
ions inside biosystems. |
---|---|
ISSN: | 1144-0546 1369-9261 |
DOI: | 10.1039/C9NJ04536H |