Microfluidic rapid and autonomous analytical device (microRAAD) to detect HIV from whole blood samples

While identifying acute HIV infection is critical to providing prompt treatment to HIV-positive individuals and preventing transmission, existing laboratory-based testing methods are too complex to perform at the point of care. Specifically, molecular techniques can detect HIV RNA within 8-10 days o...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Lab on a chip 2019-10, Vol.19 (2), p.3375-3386
Hauptverfasser: Phillips, Elizabeth A, Moehling, Taylor J, Ejendal, Karin F. K, Hoilett, Orlando S, Byers, Kristin M, Basing, Laud Anthony, Jankowski, Lauren A, Bennett, Jackson B, Lin, Li-Kai, Stanciu, Lia A, Linnes, Jacqueline C
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:While identifying acute HIV infection is critical to providing prompt treatment to HIV-positive individuals and preventing transmission, existing laboratory-based testing methods are too complex to perform at the point of care. Specifically, molecular techniques can detect HIV RNA within 8-10 days of transmission but require laboratory infrastructure for cold-chain reagent storage and extensive sample preparation performed by trained personnel. Here, we demonstrate our point-of-care microfluidic rapid and autonomous analysis device (microRAAD) that automatically detects HIV RNA from whole blood. Inside microRAAD, we incorporate vitrified amplification reagents, thermally-actuated valves for fluidic control, and a temperature control circuit for low-power heating. Reverse transcription loop-mediated isothermal amplification (RT-LAMP) products are visualized using a lateral flow immunoassay (LFIA), resulting in an assay limit of detection of 100 HIV-1 RNA copies when performed as a standard tube reaction. Even after three weeks of room-temperature reagent storage, microRAAD automatically isolates the virus from whole blood, amplifies HIV-1 RNA, and transports amplification products to the internal LFIA, detecting as few as 3 × 10 5 HIV-1 viral particles, or 2.3 × 10 7 virus copies per mL of whole blood, within 90 minutes. This integrated microRAAD is a low-cost and portable platform to enable automated detection of HIV and other pathogens at the point of care. This handheld sample-to-answer platform combines blood cell separation, viral lysis, and isothermal nucleic acid amplification with capillary fluidics and heating controls to automatically detect HIV from blood samples within 90 minutes.
ISSN:1473-0197
1473-0189
DOI:10.1039/c9lc00506d