A laser ablation resonance ionisation mass spectrometer (LA-RIMS) for the detection of isotope ratios of uranium at ultra-trace concentrations from solid particles and solutions

A commercial MALDI-TOF mass spectrometer has been combined with a tunable ns-pulse laser ionisation system consisting of two dye lasers pumped by the second (532 nm) and the third (355 nm) harmonics of a Nd:YAG laser. Uranium samples in the form of solutions, suspensions or small solid grains can be...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of analytical atomic spectrometry 2019-08, Vol.34 (8), p.163-1638
Hauptverfasser: Strashnov, Ilya, Izosimov, Igor, Gilmour, Jamie D, Denecke, Melissa Anne, Almiral, Jose, Cannavan, Andrew, Chen, Gang, Dissanayake, Champa, Doroshenko, Iryna, Elghali, Tibari, Enston, Emma, Fernando, Biyagamage Ruchika, Kasozi, Gabriel, Kelly, Simon, Maqsood, Mohammed, Muhammad, Syahidah Akmal, Muryn, Christopher, Pomerantsev, AlexeyL, Singh, Dileep Kumar, Smith, Gareth, Taous, Fouad, Webb, Carole, Williamson, David, Xu, Zhenzhen, Yang, Shuming, Zitek, Andreas
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A commercial MALDI-TOF mass spectrometer has been combined with a tunable ns-pulse laser ionisation system consisting of two dye lasers pumped by the second (532 nm) and the third (355 nm) harmonics of a Nd:YAG laser. Uranium samples in the form of solutions, suspensions or small solid grains can be placed onto an aluminium substrate without the MALDI matrix from which they are desorbed by a 337 nm nitrogen laser with a spatial resolution of 20 m. A rapid and simple sample preparation process not involving any chemical separation, pre-concentration or need for chemical derivatisation reactions is employed. The neutral uranium atoms and molecules are resonantly ionised by the photoionisation system. Highly selective and efficient uranium photoionisation schemes have been developed. They are three-colour, two-step photoionisation schemes involving resonance excitation from the ground state by a 424.23 nm laser (1 J per pulse) and subsequently by either 578.48 nm, 575.42 nm or 574.10 nm lasers (20 J per pulse) with 1064 nm (>1 mJ) ionisation into the continuum. Three-colour excitation, targeting specific uranium atomic levels, allows for selective ionisation of uranium atoms. The photo-ions have the yields of up to two orders of magnitude higher than those formed in laser desorption making them extremely suitable for the detection of isotope ratios of samples with trace concentrations. A series of measurements of reference materials with concentrations between 10 10 and 10 16 atoms per sample (10 15 to 10 7 g) and various isotope compositions ranging from depleted and natural to enriched uranium positively confirm the method applicability. For instance, for the samples of depleted uranium the 235 U/ 238 U < 0.003 ratio was determined with
ISSN:0267-9477
1364-5544
DOI:10.1039/c9ja00030e