A simple, sensitive, high-resolution, customized, reverse phase ultra-high performance liquid chromatographic method for related substances of a therapeutic peptide (bivalirudin trifluoroacetate) using the quality by design approach

Among all chemical sameness characterization tests of Therapeutic Peptides (TPs), one of the most significant and challenging aspects is to demonstrate comparable impurity profiles (both qualitative & quantitative) between a generic product and reference listed drug (RLD). Though multiple state...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Analytical methods 2020-01, Vol.12 (3), p.34-316
Hauptverfasser: Kumar, K. Y. Kiran, Dama, Venugopala Rao, Suchitra, Ch, Maringanti, Thirumala Chary
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Among all chemical sameness characterization tests of Therapeutic Peptides (TPs), one of the most significant and challenging aspects is to demonstrate comparable impurity profiles (both qualitative & quantitative) between a generic product and reference listed drug (RLD). Though multiple state of the art orthogonal analytical methods are being used for the identification and quantification of related impurities in TPs, it is important that the developed methods are simple, selective, and sensitive, and can be easily implementable in quality control laboratories. The current published chromatographic (HPLC or UHPLC) methods for the quantification of related substances in TPs rarely use non-mass spectrometry compatible ion pairing reagents (NMS-IPRs) in the mobile phase composition over mass spectrometry compatible ion pairing reagents (MS-IPRs), due to their compatibility issues with high-resolution mass-based detection methods. We hypothesize that achieving mixed mode stationary phase characteristics using hydrophobic NMS-IPRs such as sodium 1-butanesulfonate, at concentrations 2.0 between Penta-Gly & BIV, and a peak to valley ratio (Hp/Hv) > 4.0 between BIV & D-Asn and D-Asn & Tri-Gly impurities. The developed method is sensitive (LOQ ∼ 0.05% with respect to analyte concentration), precise, accurate, and linear in the range of 1 μg mL −1 to 2500 μg mL −1 . This method is rugged, robust, and easily implementable in quality control laboratories for monitoring the related impurities of bivalirudin. Among all chemical sameness characterization tests of Therapeutic Peptides (TPs), one of the most significant and challenging aspects is to demonstrate comparable impurity profiles (both qualitative & quantitative) between a generic product and reference listed drug (RLD).
ISSN:1759-9660
1759-9679
DOI:10.1039/c9ay01998g