Hydrodesulfurization Catalyst Evaluation in an Upflow Three-Phase Microreactor

The application of a fully automated upflow three-phase microreactor to evaluation of a hydrodesulfurization catalyst is illustrated. Reliable kinetic parameters are obtained, showing that solvent vaporization is carefully accounted for. Despite the small dimensions of the reactor (120 mm long, 6 mm...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Industrial & engineering chemistry research 1998-07, Vol.37 (7), p.2662-2667
Hauptverfasser: Letourneur, D, Bacaud, R, Vrinat, M, Schweich, D, Pitault, I
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The application of a fully automated upflow three-phase microreactor to evaluation of a hydrodesulfurization catalyst is illustrated. Reliable kinetic parameters are obtained, showing that solvent vaporization is carefully accounted for. Despite the small dimensions of the reactor (120 mm long, 6 mm i.d.), it is possible to define experimental conditions where plug flow prevails and gas−liquid mass transfer is instantaneous.
ISSN:0888-5885
1520-5045