Effect of Hollow Structures on T 1 and T 2 Relaxivities and Their Application in Accurate Tumor Imaging

Great progress in precisely controlling the structures of magnetic nanoparticles has been made to investigate structure–relaxivity relationships in recent years. However, the investigation of the influence of hollow structures with unique interior structures on the relaxation rate of magnetic nanopa...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Chemistry of materials 2023-09, Vol.35 (18), p.7643-7654
Hauptverfasser: Zeng, Jie, Huo, Linlin, Wang, Zhenyu, Sun, Xin, Guo, Yu, Li, Muyao, Tan, Mingya, Zhu, Shiqi, Fang, Jingqin, Zhao, Zhenghuan
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Great progress in precisely controlling the structures of magnetic nanoparticles has been made to investigate structure–relaxivity relationships in recent years. However, the investigation of the influence of hollow structures with unique interior structures on the relaxation rate of magnetic nanoparticles is rare. Herein, we obtained a series of hollow manganese-doped iron oxide nanoparticles (MnIONs) with different void and dopant ratios through a controllable etch process and systemically investigated the influence of hollow structures on the T 1/T 2 relaxation rate. Due to the increased surface-to-volume (S/V) ratio, hollow MnIO nanoparticles (HMNs) show increased T 1 relaxivity compared to solid MnIONs. The T 1 relaxivities of HMNs with different void ratios are proportion to the number of exposed magnetic ions and electronic relaxation time value, which are determined by the S/V ratio and dopant level. More importantly, HMNs exhibit reduced saturated magnetization values with increased T 2 relaxivities compared to solid MnIONs. The elevated T 2 relaxivities of HMNs are attributed to the increased number of magnetic cores per unit volume and magnetic field inhomogeneity induced by hollow structures. These parameters are highly dependent on their void ratios, thus eventually determining their T 2 relaxivities. In vivo studies demonstrate that HMNs with relatively high T 1 or T 2 relaxivity show superior sensitivity in tumor detection to traditional T 1 or T 2 contrast agents. This work summarized the effects and mechanisms of hollow structures on the T 1 and T 2 relaxation rates of magnetic nanoparticles, providing examples in vivo for the design of excellent T 1 or T 2 contrast agents (CAs) for early cancer diagnosis.
ISSN:0897-4756
1520-5002
DOI:10.1021/acs.chemmater.3c01356