Magnetic Quantum Dot Nanobead-Based Fluorescent Immunochromatographic Assay for the Highly Sensitive Detection of Aflatoxin B 1 in Dark Soy Sauce

Herein, we synthesized bifunctional magnetic fluorescent beads (MFBs) with a distinct core/shell structure by encapsulating octadecylamine-coated CdSe/ZnS QDs (OC-QDs) and oleic acid-modified iron oxide nanoparticles (OA-IONPs) into two polymer matrixes with different hydrophobic properties. The OC-...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Analytical chemistry (Washington) 2019-04, Vol.91 (7), p.4727-4734
Hauptverfasser: Guo, Liang, Shao, Yanna, Duan, Hong, Ma, Wei, Leng, Yuankui, Huang, Xiaolin, Xiong, Yonghua
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Herein, we synthesized bifunctional magnetic fluorescent beads (MFBs) with a distinct core/shell structure by encapsulating octadecylamine-coated CdSe/ZnS QDs (OC-QDs) and oleic acid-modified iron oxide nanoparticles (OA-IONPs) into two polymer matrixes with different hydrophobic properties. The OC-QDs and OA-IONPs were mainly distributed in the outer layer of MFBs. The resultant MFBs displayed ca. 226-fold stronger fluorescence emission relative to the corresponding OC-QDs and retained ca. 45.4% of the saturation magnetization of the OA-IONPs. The MFBs were used to purify and enrich aflatoxin B (AFB ) from dark soy sauce and then utilized as a fluorescent reporter of immunochromatographic assay (ICA) for the sensitive detection of AFB . Under the optimal detection conditions, the MFB-based ICA (MFB-ICA) displayed a dynamic linear detection of AFB in sauce extract over the range of 5-150 pg/mL with a half maximal inhibitory concentration of 27 ± 3 pg/mL ( n = 3). The detection limits for AFB in sauce extract and real dark soy sauce were 3 and 51 pg/mL, respectively, which are considerably better than those of the previously reported fluorescent bead-based ICA methods. The analytical performance of the proposed MFB-ICA in terms of selectivity and accuracy was investigated by analyzing AFB -spiked dark soy sauce samples. The reliability of the proposed method was further confirmed by ultraperformance liquid chromatography with fluorescence detection. With the combined advantages of QDs and IONPs, the resultant MFBs offer great potential as reporters of ICA for the sensitive detection of trace pollutants in complex matrix samples.
ISSN:0003-2700
1520-6882
DOI:10.1021/acs.analchem.9b00223