Determination of arsenic, tungsten, and antimony in natural waters by neutron activation and inorganic ion exchange
Ion exchange on Al/sub 2/O/sub 3/ columns has been used to quantitatively measure As, Sb, and W in water. This procedure requires short thermal neutron irradiations; rapid ion exchange without chemical manipulations, and short ..gamma..-ray counts on a Ge(Li) detector. Precisions of +-5% can be rout...
Gespeichert in:
Veröffentlicht in: | Anal. Chem.; (United States) 1976-12, Vol.48 (14), p.2220-2222 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Ion exchange on Al/sub 2/O/sub 3/ columns has been used to quantitatively measure As, Sb, and W in water. This procedure requires short thermal neutron irradiations; rapid ion exchange without chemical manipulations, and short ..gamma..-ray counts on a Ge(Li) detector. Precisions of +-5% can be routinely obtained and the following detection limits have been achieved: As, 0.05 ppb; Sb, 0.03 ppb; and W, 0.05 ppb. |
---|---|
ISSN: | 0003-2700 1520-6882 |
DOI: | 10.1021/ac50008a043 |