Flexural–torsional buckling of steel circular arches with I-section under central concentrated load in elevated-temperature environment
•Experiments on FTB of steel arches at elevated temperature are conducted.•The technique of importing nonuniform temperature field into the FEM of structural analysis is proposed.•The influence of the load ratio and geometrical imperfections on the critical temperature of FTB is analyzed.•Thermal ex...
Gespeichert in:
Veröffentlicht in: | Thin-walled structures 2024-03, Vol.196, p.111460, Article 111460 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | •Experiments on FTB of steel arches at elevated temperature are conducted.•The technique of importing nonuniform temperature field into the FEM of structural analysis is proposed.•The influence of the load ratio and geometrical imperfections on the critical temperature of FTB is analyzed.•Thermal expansion plays a dominant role on the FTB behavior of arches.
This article reports the fire resistance experiments conducted on I-section circular steel arches, as well as the observed out-of-plane flexural–torsional buckling (FTB) behavior and in-depth finite element numerical simulation results. The test was carried out using a large fire test furnace to provide a real fire environment with a nonuniform temperature field. A specially designed loading device allowed for unconstrained out-of-plane deformation of the specimens inside the furnace, thereby achieving effective load conditions and noncoupled response of the components. Numerical analyses were performed using a combination of the general codes Fluent and Abaqus, with the former used for heat transfer analyses, and a structural FE model including the loading device and complex geometric imperfections was established based on the measured data. Thus, accurate simulation of the out-of-plane behavior of the steel arches at elevated temperature was achieved. On this basis, an in-depth parametric study was carried out to investigate the effects of temperature field variations, load ratio (LR), and geometric imperfection. The analysis results show that FTB occurs at nonuniform temperatures for the arches under concentrated load, and the difference in temperature distribution in fire has a minimal effect on the FTB behavior. LR is negatively correlated with critical temperature; the smaller the LR, the more significant the weakening of critical loads by fire. The effect of initial geometrical imperfections on FTB at elevated temperatures is similar to that at ambient temperatures, and the effect on the critical temperature of FTB can almost be ignored when the imperfection amplitude is less than S/400. |
---|---|
ISSN: | 0263-8231 1879-3223 |
DOI: | 10.1016/j.tws.2023.111460 |