A dry chemistry, ultrasensitive microfluidic fiber material-based immunosensor for electrochemiluminescence point-of-care testing of luteinizing hormone

Luteinizing hormone (LH) is a gonadotropin, and its concentration is closely related to the female ovulation cycle. However, the traditional lateral flow method for LH detection has poor sensitivity and sustainability. In this work, a dry chemistry, ultrasensitive microfluidic fiber material-based i...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Sensors and actuators. B, Chemical Chemical, 2023-10, Vol.393, p.134259, Article 134259
Hauptverfasser: Xue, Kaifa, Lin, Baoyu, Huang, Shiju, Cai, Bolin, Lai, Wei, Zhan, Tingting, Liang, Yi, Zhang, Chunsun
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Luteinizing hormone (LH) is a gonadotropin, and its concentration is closely related to the female ovulation cycle. However, the traditional lateral flow method for LH detection has poor sensitivity and sustainability. In this work, a dry chemistry, ultrasensitive microfluidic fiber material-based immunosensor (μFIS) has been firstly proposed for electrochemiluminescence (ECL) point-of-care testing (POCT) of LH. The μFIS was composed of four-layer fiber material (paper and cloth)-based pads, and was combined with closed bipolar electrode-ECL (CBPE-ECL) to quantitatively detect LH. The CBPE-ECL μFIS not only retained the high sensitivity and wide linear range associated with CBPE-ECL, but also reserved the simplicity and practicality of the lateral flow assay. In addition, a self-enhanced intramolecular ECL probe was incorporated into the μFIS for signal amplification. Under optimized conditions, the μFIS had a very low detection limit (0.125 μIU mL-1) and positive linear relationship (0.001–100 mIU mL-1), together with excellent selectivity, reproducibility and storage stability. Moreover, the CBPE-ECL μFIS was applied to detect LH in human clinical serum samples, and the results had a good correlation with those of clinical samples. These results revealed that the CBPE-CEL μFIS had the potential as a high-performance POCT for LH or other biomarkers. [Display omitted] •A novel dry chemistry-based ECL immuosensor was applied for detection of LH.•The self-enhanced Ru(II)-PLL complex was applied for ultrasensitive detection.•The microfluidic chip was easily fabricated with cloth and filter paper.•The automatic portable ECL analyzer was used for rapid detection (about 8 min).•The detection limit was 0.125 μIU mL-1, and the linear range is from 0.001 to100 mIU mL-1.
ISSN:0925-4005
1873-3077
DOI:10.1016/j.snb.2023.134259