A specific short peptide-assisted enhanced chemiluminescence resonance energy transfer (CRET) for label-free and ratiometric detection of copper ions in complex samples

A specific short peptide-assisted enhanced chemiluminescence resonance energy transfer system was constructed and applied to facile ratiometric detection of Cu2+ in serum [Display omitted] •SPGH dramatically enhanced the catalytic activity of Cu2+ was confirmed for the first time.•The enhancement me...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Sensors and actuators. B, Chemical Chemical, 2020-10, Vol.320, p.128411, Article 128411
Hauptverfasser: Xiong, Yamin, Zhou, Lihong, Peng, Xiaoxia, Li, Huiling, Wang, Hui, He, Leiliang, Huang, Peili
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A specific short peptide-assisted enhanced chemiluminescence resonance energy transfer system was constructed and applied to facile ratiometric detection of Cu2+ in serum [Display omitted] •SPGH dramatically enhanced the catalytic activity of Cu2+ was confirmed for the first time.•The enhancement mechanism mainly due to the significantly increasing generation of Cu-induced ⋅OH after the addition of SPGH.•Peptide-assisted enhanced CRET has been constructed for ratiometric detection of Cu2+.•The anti-interference ability has been improved by using ratiometric signal. Convenient and rapid detection of Cu2+ in serum has important clinical significance for related diseases. Herein, a ratiometric detection of Cu2+ based on specific short peptide (SPGH)-assisted enhanced chemiluminescence resonance energy transfer (CRET) has been constructed. An interesting phenomenon that tetra-peptide with the sequence of Ser-Pro-Gly-His (SPGH) was able to specifically and remarkably enhance the catalytic performance of Cu2+ has been discovered, the enhancement mechanism is mainly due to the significant increasing generation of Cu2+-induced hydroxyl radical after addition of SPGH. The chemiluminescence (CL) of the luminol-H2O2 system was efficiently catalyzed by the formed Cu(SPGH)2 complex, which acts as an internal light source to triggers on the fluorescence of QDs via CRET, allowing the ratiometric detection of Cu2+ within 15 min with improved selectivity and sensitivity. The relative standard deviation was lower than 6.38 % due to the ratiometric signal improving its anti-interference ability. Importantly, it is feasible to detect total Cu in human serum, and the results were consistent with that of ICP-AES (r = 0.9321, n=55). The reliable, rapid, yet simple ratiometric detection of Cu2+ in serum based on SPGH-assisted enhanced CRET provides a promising potential alternative method for Cu2+ detection in clinical application.
ISSN:0925-4005
1873-3077
DOI:10.1016/j.snb.2020.128411