Correction of self-absorption effect in laser-induced breakdown spectroscopy based on temperature iteration

Laser-induced breakdown spectroscopy (LIBS) is an ideal real-time on-line method for the detection of minor elements in alloy steel, but it needs to solve the undesired self-absorption effect in plasma. Since the plasma electron temperature (T), radiation particle number density and absorption path...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Spectrochimica acta. Part B: Atomic spectroscopy 2024-05, Vol.215, p.106925, Article 106925
Hauptverfasser: Hou, Jiajia, Zhang, Dacheng, Feng, Zhongqi, Zhu, Jiangfeng, Zhang, Lei
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Laser-induced breakdown spectroscopy (LIBS) is an ideal real-time on-line method for the detection of minor elements in alloy steel, but it needs to solve the undesired self-absorption effect in plasma. Since the plasma electron temperature (T), radiation particle number density and absorption path length (Nl) determine the degree of self-absorption and affect the corrected spectral line intensity, a new temperature iterative self-absorption correction method based on the plasma thermal equilibrium radiation model is proposed to continuously calculate and correct these two parameters. Compared with generally applied self-absorption correction methods, this method has obvious advantages of simple programming, high computational efficiency, and independence of the availability or accuracy of Stark broadening coefficients. The quantitative analysis results of Cu show that the linearity of calibration curves and the measurement accuracy of elemental content are significantly improved with the self-absorption correction. In addition, this method can directly obtain the accurate radiation particle number density and absorption path length, which benefits the plasma diagnostics and quantitative analysis. [Display omitted] •A quantitative relationship model between self-absorption and parameters of spectral line and plasma was established.•The proposed method is based on temperature iteration and does not need the Stark broadening coefficient.•The proposed method can directly obtain the accurate radiation particle number density and absorption path length.•Experimental results proved that both the linearity of the Boltzmann plot and the measurement accuracy was improved.
ISSN:0584-8547
1873-3565
DOI:10.1016/j.sab.2024.106925