CdTe QDs@ZIF-8 composite-based recyclable ratiometric fluorescent sensor for rapid and sensitive detection of chlortetracycline
[Display omitted] •CdTe QDs@ZIF-8 composite achieved the ratiometric sensing of chlortetracycline.•The composite exhibited excellent recyclability, rapid response and high sensitivity.•The composite was applied to analyzing chlortetracycline in basa fish and pure milk.•Fluorescent test strips were f...
Gespeichert in:
Veröffentlicht in: | Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy Molecular and biomolecular spectroscopy, 2022-04, Vol.270, p.120785, Article 120785 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | [Display omitted]
•CdTe QDs@ZIF-8 composite achieved the ratiometric sensing of chlortetracycline.•The composite exhibited excellent recyclability, rapid response and high sensitivity.•The composite was applied to analyzing chlortetracycline in basa fish and pure milk.•Fluorescent test strips were further manufactured for the purpose of convenience.
The residue problem in animal food products caused by the abuse of chlortetracycline (CTC) is one of the food safety issues that have attracted much attention. Herein, a composite was generated by embedding CdTe quantum dots (QDs) into ZIF-8 for ratiometric fluorescent analysis of CTC. With adding CTC, the green luminescence of CTC appeared under the sensitization effect of Zn2+ in ZIF-8, but the red luminescence of CdTe QDs was reduced by the inner filtration effect of CTC. On this basis, CTC was detected by the composite with a short response time of 1 min, and the limit of detection was calculated to be 37 nM that was 17 times lower than the maximum residue limit of CTC in animal food products (626 nM). Excellent recyclability of the composite was also observed, and CTC was consecutively measured at least six times. The composite was used to determine CTC in basa fish and pure milk with satisfactory recoveries (91.0–110.0%). Portable test strips were further manufactured and the visual determination of CTC was obtained. These results convictively demonstrate that CdTe QDs@ZIF-8 composite as a recyclable ratiometric fluorescent sensor achieves the rapid and sensitive measurement of CTC residue in animal food products. |
---|---|
ISSN: | 1386-1425 1873-3557 |
DOI: | 10.1016/j.saa.2021.120785 |