Performance evaluation of nitrogen for fire safety application in aircraft

•The title of the topic was changed to: performance evaluation of nitrogen for fire safety application in aircraft.•Simulation of cup-burner test through CFD.•Reconsider the pool-fire case in CFD.•Meaningful discussion and conclusion regarding the observations made during this study.•Additional refe...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Reliability engineering & system safety 2020-10, Vol.202, p.107044, Article 107044
Hauptverfasser: Dinesh, A., Benson, C.M., Holborn, P.G., Sampath, S., Xiong, Y.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:•The title of the topic was changed to: performance evaluation of nitrogen for fire safety application in aircraft.•Simulation of cup-burner test through CFD.•Reconsider the pool-fire case in CFD.•Meaningful discussion and conclusion regarding the observations made during this study.•Additional references were included from RESS journal. Fire suppression is an important safety certification requirement for aircraft as it is for all safety critical systems. Risk analyses are required at the design and certification stages to determine the probabilities and means of mitigating such risks. Apostolakis et al. (1995) shows an approach for spacecraft, Spyrou and Koromila (2020) for passenger ships and Arshi et al. (2010) for reactors. An important analysis tool for aircraft is the Zonal Analysis process (Chen and Fielding, 2018) Such analyses include investigation of means of fire suppression for which the use of Halon 1301 was a popular choice. The production of Halon and several halocarbons were banned under the Montreal Protocol in 1994, which necessitates an investigation for use of environmental-friendly agents for this application. The primary objective of this paper is to determine the ‘design concentration’11Design concentration is the volumetric concentration of the agent to achieve successful fire suppression in an enclosure. of nitrogen required for fire suppression. Computational Fluid Dynamics (CFD), in combination with experimental verification is described in this paper. The air flow rate in the cup-burner model was varied between 10 L/min and 40 L/min for a low-speed numerical model and was validated against the BS ISO 14520 cup burner test (BS ISO 14520 Annex, 2006) to determine the extinguishing concentration of nitrogen. The study revealed that the design concentration of nitrogen was 34% (14% oxygen concentration). Further investigation suggested that at low air flow rates (10 L/min and 20 L/min case), distortions produced in the flow led to erroneous measurement of oxygen concentration in experiments. The fire suppression model was extended to an n-heptane pool fire in a large enclosure. The recorded design concentration was approximately 39% additional nitrogen corresponding to 13% oxygen concentration by volume. It was observed that the weight of nitrogen required increased by 7.5 times compared to Halon 1301 use for this model. Future work can be explored in aircraft cargo and engine bay fire safety systems through Minimum Performance Sta
ISSN:0951-8320
1879-0836
DOI:10.1016/j.ress.2020.107044