Evaluation of radiation dose and radiation-induced cancer risk associated with routine CT scan examinations
Using patient-specific data, the present study aimed to identify organ and effective dose to estimate the lifetime attributable risks (LARs) of cancer incidence and mortality associated with routine CT procedures. A cross-sectional investigation was conducted on 515 patients who underwent CT scan. T...
Gespeichert in:
Veröffentlicht in: | Radiation physics and chemistry (Oxford, England : 1993) England : 1993), 2024-04, Vol.217, p.111521, Article 111521 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Using patient-specific data, the present study aimed to identify organ and effective dose to estimate the lifetime attributable risks (LARs) of cancer incidence and mortality associated with routine CT procedures. A cross-sectional investigation was conducted on 515 patients who underwent CT scan. The effective dose was computed using two methods: first, the ImPACT software and relevant conversion factors. Second, the effective dose was determined using the scanner-derived DLP and AAPM TG 23's conversion factor. Using the biological effects of ionizing radiation (BEIR VII) report, LAR of cancer incidence and mortality were computed. The greatest mean organ doses for abdomen-pelvis, routine chest, chest HRCT, brain, and sinus examinations were 20.64 ± 3.27 mGy (kidneys), 21.55 ± 5.47 mGy (thymus and esophagus), 10.51 ± 1.31 mGy (thymus and esophagus), 22.72 ± 3.01 mGy (lens), and 18.56 ± 1.25 mGy (lens) respectively. Using ImPACT dosimetry software, the mean effective dose for routine chest, abdomen-pelvis, HRCT chest, brain, and sinus examinations was 8.46 mSv, 10.13 mSv, 4.19 mSv, 1 mSv, and 0.68 mSv, respectively. Using the DLP to effective dose conversion factor, the mean effective dose was lower. The mean cancer incidence risks per 100,000 people were 63.33, 54.98, 27.82, 6.31, and 5.22 for abdomen-pelvis, routine chest, HRCT, brain, and sinus examinations, respectively. The mean LAR of cancer mortality for all cancer was 38.22, 33.17, 16.72, 3.87, 2.93 for abdomen-pelvis, routine chest, HRCT, brain, and sinus examinations, respectively, per 100,000 people. Thus, CT scan exams are connected with a non-negligible risk of cancer, and patient radiation dose must be optimized to limit radiation risk.
•The effective dose of routine CT examinations was calculated by two methods.•Abdomen-pelvis scans had the highest mean DLP, scan length, and effective dose.•The current study's CTDIvol and DLP were below recognized diagnostic reference levels.•The abdomen-pelvis had the highest mean LAR of all cancers, all solid, and leukemia, respectively, at 63.33, 56.56, and 6.77. |
---|---|