Investigation of the effect of crystal dead layer on system performance in Single Photon Emission Computed Tomography: A Monte Carlo simulation study

One of the factors affecting image quality in SPECT (Single Photon Emission Computed Tomography) applications is the dead layer that forms over time in the scintillation crystal. In this study, we aimed to investigate the effect of dead layers in the NaI(Tl) scintillation crystal used in SPECT on sy...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Radiation measurements 2025-02, Vol.181, p.107363, Article 107363
Hauptverfasser: Uslu Aynur, Hilal, Bayram, Tuncay, Hayder, Anes, Gedik, Sonay
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:One of the factors affecting image quality in SPECT (Single Photon Emission Computed Tomography) applications is the dead layer that forms over time in the scintillation crystal. In this study, we aimed to investigate the effect of dead layers in the NaI(Tl) scintillation crystal used in SPECT on system performance. The GATE simulation code, which is based on the GEANT4 toolkit and is widely recognized for its application in nuclear imaging simulations, was employed for this investigation. In the first step, the standard SPECT model was simulated, and the SPECT performance parameters (sensitivity, spatial resolution, energy resolution, and contrast) for low 140 keV (for 99mTc), medium 167 keV (for 201Tl), and high 364 keV (for 131I) gamma energies have been analyzed. Then, various thicknesses of dead layers on the crystal were simulated, and the effect of the dead layer on the performance parameters was evaluated for the same energies. The results indicate a reduction in SPECT sensitivity of approximately 33.5%, 27.1%, and 21.7% for low, medium, and high energies, respectively, as the thickness of the crystal’s dead layer increases from 0.19 mm to 1.52 mm (equivalent to 2% to 16%). Small deteriorations in spatial resolution and energy resolution of the SPECT have been determined for 140 keV, 167 keV, and 364 keV gamma energies. The dead layers slightly influenced the contrast of SPECT. The results of this study show that the image quality assessment parameters of the SPECT system deteriorated as the thickness of the scintillation crystal’s dead layer increased. •The image quality performance parameters of the SPECT system deteriorate as the thickness of the scintillation crystal’s dead layer increased.•The sensitivity of SPECT reduces when the crystal’s dead layer increases.•Small deteriorations in spatial resolution and energy resolution of the SPECT are seen in the existence of a crystal dead layer.•The contrast of SPECT is slightly influenced by the crystal dead layer.
ISSN:1350-4487
DOI:10.1016/j.radmeas.2024.107363