Geologic variability of conodont strontium isotopic composition quantified by laser ablation multiple collection inductively coupled plasma mass spectrometry

Conodont microfossils record seawater strontium isotope values (87Sr/86Sr), permitting chemostratigraphic correlation for tectonic and climatic reconstructions of the Paleozoic and early Mesozoic (541–201 Ma). Laser ablation multiple collection inductively coupled plasma mass spectrometry (LA MC-ICP...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Palaeogeography, palaeoclimatology, palaeoecology palaeoclimatology, palaeoecology, 2021-04, Vol.568, p.110308, Article 110308
Hauptverfasser: Griffin, Julie M., Montañez, Isabel P., Glessner, Justin J.G., Chen, Jitao, Willmes, Malte
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Conodont microfossils record seawater strontium isotope values (87Sr/86Sr), permitting chemostratigraphic correlation for tectonic and climatic reconstructions of the Paleozoic and early Mesozoic (541–201 Ma). Laser ablation multiple collection inductively coupled plasma mass spectrometry (LA MC-ICP-MS) can provide rapid, high spatial resolution 87Sr/86Sr analysis of conodont bioapatite but has not been validated by comparison with solution analysis. Validation of LA MC-ICP-MS should be completed in order to use the conodont 87Sr/86Sr values for age-correlations and environmental interpretations. Here, for the first time, we compare solution and LA MC-ICP-MS 87Sr/86Sr analyses of Carboniferous-age conodonts. Furthermore, we use quadrupole LA ICP-MS to determine concentrations of trace elements potentially responsible for isobaric interferences. Using increased mass resolving power (m/∆m = ~7500) and analyzing conodont tissue with low 85Rb/88Sr (< 0.001), we find laser ablation copacetic with solution 87Sr/86Sr values. The two-standard-deviation of these LA 87Sr/86Sr ratios (average 2SD = 0.00105) are within the two-standard-error uncertainty of solution measurements (average 2SE = 0.00001) on conodonts from the same stratigraphic level. The LA measurements are at a higher spatial resolution and on average 0.00015 higher than solution measurements. Uncertainty of the mean calculations, made on duplicate LA MC-ICP-MS analyses of individual conodonts from the same stratigraphic level, exhibit 87Sr/86Sr variability beyond the precision of reference materials (2SE = 0.00001). This finding suggests that solution 87Sr/86Sr values determined by dissolving multiple conodonts are homogenizing the conodont 87Sr/86Sr signal. As such, the precision of these solution measurements does not capture the geologic variability of conodont 87Sr/86Sr within a stratigraphic level, which may originate from differential diagenetic alteration. Conodont 87Sr/86Sr measurements that do not account for this variability are at risk of false calibrations with the paleo-seawater 87Sr/86Sr curve, which has implications for the timing of geologic events and reconstructions of paleo-environmental changes. •Medium mass resolution LA MC-ICP-MS of conodont 87Sr/86Sr yields values equivalent to solution.•Duplicate conodont LA MC-ICP-MS analyses exhibit 87Sr/86Sr variability homogenized by solution.•LA MC-ICP-MS analysis of conodonts is rapid, accurate, and reveals geologic 87Sr/86Sr variation.
ISSN:0031-0182
1872-616X
DOI:10.1016/j.palaeo.2021.110308