Identification of multi-dimensional thread geometry using depth-resolved swept-source optical coherence tomography for assessment of dental implant fabrication

•The swept-source optical coherence tomography was utilized to visualize the geometry of dental implants.•The developed boundary flattening algorithm evaluated the surface roughness.•The cross-sections and volume renders revealed various parameters of implant thread geometry.•The depth of thread was...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Optics and lasers in engineering 2020-04, Vol.127, p.105951, Article 105951
Hauptverfasser: Lee, Jaeyul, Han, Sangyeob, Hwang, Junho, Park, Sungjo, Jeon, Deokmin, Kim, Kanghae, Wijesinghe, Ruchire Eranga, Lee, Kyu-Bok, Jeon, Mansik, Kim, Jeehyun
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:•The swept-source optical coherence tomography was utilized to visualize the geometry of dental implants.•The developed boundary flattening algorithm evaluated the surface roughness.•The cross-sections and volume renders revealed various parameters of implant thread geometry.•The depth of thread was clearly measured using a depth-directional intensity profile.•The method demonstrated the applicability for the enhancement of quality and stability after fabrications. The geometrical characteristics of dental implants, such as thread depth and width, facing angle, pitch, and surface roughness, are important to assess their stability and osseointegration after implant surgery. Herein, we demonstrate the potential use of depth-resolved swept-source optical coherence tomography (SS-OCT) to assess the structural quality of widely used dental implants. The implemented SS-OCT system was centered at a wavelength of 1300 nm with a 100 nm full-width at half-maximum. Four dental implants with different structural formations fabricated using either titanium or ceramic were visualized. Qualitative assessments were performed using boundary flattening with an amplitude-profiling algorithm to emphasize and compare the thread depths, surface roughness, and inner structures of the experimental samples. Cross-sectional and volumetric OCT data clearly revealed the depth, width, and pitch of the dental implants, and especially, the quantitative assessment of axial and lateral thread depth unobtainable using conventional inspection methods was successfully conducted. The depth of thread was measured using a depth-directional intensity profile. In conclusion, the high-resolution SS-OCT system could be utilized to improve the quality assurance of dental implant products through multi-plane assessment.
ISSN:0143-8166
1873-0302
DOI:10.1016/j.optlaseng.2019.105951