Development of 64-channel LSI with ultrafast analog and digital signal processing dedicated for photon-counting computed tomography with multi-pixel photon counter

X-ray computed tomography (CT) is non destructive visualization inside the human body. Recently, X-ray photon-counting CT (PC-CT) has drawn attention for reducing the high doses used for patients and acquiring spectral information to identify materials. To enable photon-counting imaging with a wide...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment Accelerators, spectrometers, detectors and associated equipment, 2023-02, Vol.1047, p.167721, Article 167721
Hauptverfasser: Arimoto, Makoto, Sato, Daichi, Mizuno, Tomoya, Yoshiura, Kotaro, Ishiguro, Kairi, Tomoda, Takahiro, Kawashima, Hiroki, Kobayashi, Satoshi, Kataoka, Jun, Sagisaka, Mayu, Ikeda, Hirokazu, Terazawa, Shinsuke, Shiota, Satoshi
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:X-ray computed tomography (CT) is non destructive visualization inside the human body. Recently, X-ray photon-counting CT (PC-CT) has drawn attention for reducing the high doses used for patients and acquiring spectral information to identify materials. To enable photon-counting imaging with a wide region (∼60 mm long) of a small animal, we developed a photon-counting system using a 64-channel multi-pixel photon counter (MPPC) array with a fast temporal response (a few nanoseconds) and a very large signal gain (∼106), combined with a 64-channel yttrium–gadolinium–aluminum–gallium garnet scintillator array. In particular, to realize ultra-fast analog and digital signal processing (>10 MHz/channel), we developed a 64-channel large-scale integrated circuit (LSI) named MPPC-CT64. We had previously developed a 16-channel PC-CT system with a 16-channel LSI (MPPC-CT16). Although the MPPC-CT16 realized photon-counting imaging for a ∼16-mm-long phantom, there were some energy uncertainties in the LSI, which degraded the obtained CT image quality. The MPPC-CT64 implements a function for correcting the threshold energies and also increases the number of energy thresholds from four to six, which provides more precise measurements of CT values dependent on X-ray energy. In this paper, we briefly present the electric architecture and performance evaluation of the LSI combined with MPPCs.
ISSN:0168-9002
1872-9576
DOI:10.1016/j.nima.2022.167721